Status | Score | Responsible Party |
---|---|---|
1.79 / 8.00 |
Gross Scope 1 and Scope 2 greenhouse gas (GHG) emissions:
Performance year | Baseline year | |
Gross Scope 1 GHG emissions from stationary combustion | 5,988 Metric tons of CO2 equivalent | 6,063 Metric tons of CO2 equivalent |
Gross Scope 1 GHG emissions from other sources | 300 Metric tons of CO2 equivalent | 355 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported electricity | 3,532 Metric tons of CO2 equivalent | 3,267 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported thermal energy | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Total | 9,820 Metric tons of CO2 equivalent | 9,685 Metric tons of CO2 equivalent |
Figures needed to determine net carbon sinks:
Performance year | Baseline year | |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from non-additional sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon sold or transferred | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Net carbon sinks | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
A brief description of the carbon sinks, including vendor, project source, verification program and contract timeframes (as applicable):
Adjusted net Scope 1 and Scope 2 GHG emissions:
Performance year | Baseline year | |
Adjusted net GHG emissions | 9,820 Metric tons of CO2 equivalent | 9,685 Metric tons of CO2 equivalent |
Start and end dates of the performance year and baseline year (or three-year periods):
Performance year | Baseline year | |
Start date | July 1, 2021 | July 1, 2017 |
End date | June 30, 2022 | June 30, 2018 |
A brief description of when and why the GHG emissions baseline was adopted:
Figures needed to determine “Weighted Campus Users”:
Performance year | Baseline year | |
Number of students resident on-site | 361 | 487 |
Number of employees resident on-site | 4 | 4 |
Number of other individuals resident on-site | 0 | 0 |
Total full-time equivalent student enrollment | 1,500 | 1,795 |
Full-time equivalent of employees | 226 | 269 |
Full-time equivalent of students enrolled exclusively in distance education | 651 | 646 |
Weighted Campus Users | 897.50 | 1,186.25 |
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user:
Performance year | Baseline year | |
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user | 10.94 Metric tons of CO2 equivalent | 8.16 Metric tons of CO2 equivalent |
Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
Gross floor area of building space, performance year:
Floor area of energy intensive building space, performance year:
Floor area | |
Laboratory space | 72,842 Square feet |
Healthcare space | 0 Square feet |
Other energy intensive space | 18,786 Square feet |
EUI-adjusted floor area, performance year:
Adjusted net Scope 1 and 2 GHG emissions per unit of EUI-adjusted floor area, performance year:
A brief description of the institution’s GHG emissions reduction initiatives:
Website URL where information about the institution's GHG emissions is available:
Additional documentation to support the submission:
Data source(s) and notes about the submission:
Number of employees resident on-site was not available for FY18. Inserted 4 as a proxy from FY22. FY21 had 3 employees residing on site so there is some evidence that this is a consistent number of people.
Note the GSF includes buildings that may be rarely used/occupied and do not have heat (storage/barns). The NWROC Agriculture Research Center would also be supplied by Crookston's steam system (12,604 square feet), but is not within the STARS boundary and is not included in the GSF.
Number of employees resident on-site was not available for FY18. Inserted 4 as a proxy from FY22. FY21 had 3 employees residing on site so there is some evidence that this is a consistent number of people.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.