Overall Rating | Gold - expired |
---|---|
Overall Score | 68.31 |
Liaison | Lisa Noriega |
Submission Date | Aug. 3, 2020 |
Yale University
OP-2: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
3.33 / 8.00 |
Lindsay
Crum Chief Manager for Sustainability Operations & Strategic Data Yale Office of Sustainability |
"---"
indicates that no data was submitted for this field
Scope 1 and Scope 2 GHG emissions
Gross GHG emissions
Performance year | Baseline year | |
Gross Scope 1 GHG emissions from stationary combustion | 197,431 Metric tons of CO2 equivalent | 212,388 Metric tons of CO2 equivalent |
Gross Scope 1 GHG emissions from other sources | 3,461 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported electricity | 9,929 Metric tons of CO2 equivalent | 47,029 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported thermal energy | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Total | 210,821 Metric tons of CO2 equivalent | 259,417 Metric tons of CO2 equivalent |
Carbon sinks
Performance year | Baseline year | |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from non-additional sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon sold or transferred | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Net carbon sinks | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
If total performance year carbon sinks are greater than zero, provide:
n/a
Adjusted net GHG emissions
Performance year | Baseline year | |
Adjusted net GHG emissions | 210,821 Metric tons of CO2 equivalent | 259,417 Metric tons of CO2 equivalent |
Performance and baseline periods
Performance year | Baseline year | |
Start date | July 1, 2018 | July 1, 2004 |
End date | June 30, 2019 | June 30, 2005 |
A brief description of when and why the GHG emissions baseline was adopted:
n/a
Part 1. Reduction in GHG emissions per person
Weighted campus users
Performance year | Baseline year | |
Number of students resident on-site | 6,048 | 5,546 |
Number of employees resident on-site | 59 | 0 |
Number of other individuals resident on-site | 101 | 0 |
Total full-time equivalent student enrollment | 13,368 | 11,359 |
Full-time equivalent of employees | 15,580 | 11,241 |
Full-time equivalent of students enrolled exclusively in distance education | 0 | 0 |
Weighted Campus Users | 23,338.75 | 18,336.50 |
Metrics used in scoring for Part 1
Performance year | Baseline year | |
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user | 9.03 Metric tons of CO2 equivalent | 14.15 Metric tons of CO2 equivalent |
Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
36.15
Part 2. GHG emissions per unit of floor area
Performance year floor area
16,587,016
Gross square feet
Floor area of energy intensive building space, performance year:
Floor area | |
Laboratory space | 722,973 Square feet |
Healthcare space | 358,581 Square feet |
Other energy intensive space | 1,206,439 Square feet |
EUI-adjusted floor area, performance year:
19,956,563
Gross square feet
Metric used in scoring for Part 2
0.01
MtCO2e per square foot
A brief description of the institution’s GHG emissions reduction initiatives:
---
Website URL where information about the institution's GHG emissions is available:
---
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
Number of other individuals resident on-site and/or in-patient hospital beds was not available for FY05, so we entered 0.
GHG data does not include West Campus, so all square footage data has been adjusted to exclude WC - this accounts for discrepancy in square footage data between this credit and other sections.
GHG data does not include West Campus, so all square footage data has been adjusted to exclude WC - this accounts for discrepancy in square footage data between this credit and other sections.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.