Overall Rating Silver - expired
Overall Score 47.51
Liaison Mike Evans
Submission Date Feb. 2, 2016
Executive Letter Download

STARS v2.0

Williams College
OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 3.71 / 10.00 Amy Johns
Director
Zilkha Center for Environmental Initiatives
"---" indicates that no data was submitted for this field

None
Does the institution's GHG emissions inventory include all Scope 1 and Scope 2 GHG emissions?:
Yes

None
Does the institution's GHG emissions inventory include all Scope 3 GHG emissions from any of the following categories?:
Yes or No
Business travel Yes
Commuting Yes
Purchased goods and services No
Capital goods No
Fuel- and energy-related activities not included in Scope 1 or Scope 2 No
Waste generated in operations Yes

None
Does the institution's GHG emissions inventory include Scope 3 emissions from other categories?:
No

None
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
The GHG emissions inventory was completed using data collected from all relevant college operating departments. The calculations were conducted using the Clean Air - Cool Planet Campus Carbon Calculator.

None
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

None
A brief description of the internal and/or external verification process:
The report has been validated internally by senior staff and the campus environmental advisory committee.

None
Scope 1 and Scope 2 GHG emissions::
Performance Year Baseline Year
Scope 1 GHG emissions from stationary combustion 13,315 Metric tons of CO2 equivalent 13,382 Metric tons of CO2 equivalent
Scope 1 GHG emissions from other sources 405 Metric tons of CO2 equivalent 576 Metric tons of CO2 equivalent
Scope 2 GHG emissions from purchased electricity 13,537 Metric tons of CO2 equivalent 9,585 Metric tons of CO2 equivalent
Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

None
Figures needed to determine total carbon offsets::
Performance Year Baseline Year
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Third-party verified carbon offsets purchased 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

None
A brief description of the institution-catalyzed carbon offsets program:
---

None
A brief description of the carbon sequestration program and reporting protocol used:
---

None
A brief description of the composting and carbon storage program:
---

None
A brief description of the purchased carbon offsets, including third party verifier(s) and contract timeframes:
---

None
Figures needed to determine “Weighted Campus Users”::
Performance Year Baseline Year
Number of residential students 1,973 1,925
Number of residential employees 136 124
Number of in-patient hospital beds 0 0
Full-time equivalent enrollment 2,079 2,056
Full-time equivalent of employees 1,064 818
Full-time equivalent of distance education students 0 0

None
Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year July 1, 2013 June 30, 2014
Baseline Year July 1, 1990 June 30, 1991

None
A brief description of when and why the GHG emissions baseline was adopted:
We adopted 1991 as our baseline because that's the earliest year that we have comprehensive records.

None
Gross floor area of building space, performance year:
2,491,400 Square feet

None
Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 258,401 Square feet
Healthcare space 7,016 Square feet
Other energy intensive space 24,885 Square feet

None
Scope 3 GHG emissions, performance year::
Emissions
Business travel 1,893 Metric tons of CO2 equivalent
Commuting 2,367 Metric tons of CO2 equivalent
Purchased goods and services ---
Capital goods ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 ---
Waste generated in operations 759.45 Metric tons of CO2 equivalent
Other categories (please specify below) ---

None
A brief description of the sources included in Scope 3 GHG emissions from "other categories":
---

None
A copy of the most recent GHG emissions inventory:
None
The website URL where the GHG emissions inventory is posted:
None
A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
Williams actively invests in energy conservation and efficiency projects in campus buildings. We burned lower emitting fossil fuels in our central heating plant.

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.