SD-9: Energy Initiatives

Status Score Responsible Party
Complete N/A Robert Hickman
Operations Mgr, Energy Efficiency
Facilities
"---" indicates that no data was submitted for this field

The percentage of total building space square footage that has undergone energy retrofits or renovations within the past three years:
65

The percentage of overall energy consumption reduced as a result of retrofits and renovations completed within the past three years:
32

The percentage of electricity consumption reduced as a result of retrofits and renovations completed within the past three years:
31.50

The percentage of thermal energy consumption reduced as a result of retrofits and renovations completed within the past three years:
25

The combined gross square footage of all buildings that were constructed or underwent renovations in the past three years that are ENERGY STAR labeled:
0

The names of all buildings that were constructed or underwent renovations in the past three years that are ENERGY STAR labeled:
---

The combined gross square footage of all buildings that are ENERGY STAR labeled:
0

The names of all buildings that are ENERGY STAR labeled:
---

Data source(s) and notes about the submission:

100% of our East Campus was retrofitted from air-cooled to water-cooled chiller plant with central distribution, Building Automation System (BAS) and lighting controls. Our West Campus has a high-efficiency chiller, completed distribution loop. Removing a defective old natural gas boiler saved $150,000/yr replacing it with two 10 million BTU boilers. Osceola Campus changed from air-cooled to water-cooled chillers and added lighting controls. CJI added thermal storage and BAS. Winter Park added an energy efficient chiller. On West lighting in breezeways was changed from high-pressure sodium to induction lighting. In parking lot lights were changed from high-pressure sodium to metal halide.


100% of our East Campus was retrofitted from air-cooled to water-cooled chiller plant with central distribution, Building Automation System (BAS) and lighting controls. Our West Campus has a high-efficiency chiller, completed distribution loop. Removing a defective old natural gas boiler saved $150,000/yr replacing it with two 10 million BTU boilers. Osceola Campus changed from air-cooled to water-cooled chillers and added lighting controls. CJI added thermal storage and BAS. Winter Park added an energy efficient chiller. On West lighting in breezeways was changed from high-pressure sodium to induction lighting. In parking lot lights were changed from high-pressure sodium to metal halide.

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.