Overall Rating Silver - expired
Overall Score 61.37
Liaison Suzanne Davis
Submission Date Oct. 26, 2020

STARS v2.2

University of Queensland
OP-6: Clean and Renewable Energy

Status Score Responsible Party
Complete 0.24 / 4.00
"---" indicates that no data was submitted for this field

Total energy consumption, performance year:
510,749.79 MMBtu

Clean and renewable electricity (report kilowatt-hours):
kWh MMBtu
Imported electricity from certified/verified clean and renewable sources (i.e., bundled green power purchases) 0 Kilowatt-hours 0 MMBtu
Electricity from on-site, clean and renewable sources (rights retained/retired) 8,968,503.41 Kilowatt-hours 30,600.53 MMBtu

A brief description of the certified/verified sources of clean and renewable electricity:
---

A brief description of the on-site renewable electricity generating facilities/devices:

6.4 Megawatts of behind the meter solar photovoltaic arrays installed, owned and operated by UQ, across multiple campuses.
Information on UQ's renewable energy program online:
https://sustainability.uq.edu.au/sustainability-themes/renewable-energy
Information on UQ's solar facilities and campus locations. Please follow the links to the various campuses to see installations:
https://solar-energy.uq.edu.au/facilities


Clean and renewable thermal energy (report MMBtu):
MMBtu
Clean and renewable stationary fuels used on-site to generate thermal energy 0 MMBtu
Imported steam, hot water, and/or chilled water from certified/verified clean and renewable sources 0 MMBtu

A brief description of the clean and renewable stationary fuels:

UQ thermal energy is derived from electricity therefore is caputured above


A brief description of the certified/verified sources of clean and renewable thermal energy:
---

Unbundled renewable energy products (report kWh):
kWh MMBtu
Purchased RECs, GOs, I-RECs or equivalent unbundled renewable energy products certified by a third party 0 Kilowatt-hours 0 MMBtu

A brief description of the unbundled renewable energy products:
---

Total clean and renewable energy generated or purchased:
30,600.53 MMBtu

Percentage of total energy consumption from clean and renewable sources:
5.99

Website URL where information about the institution’s support for clean and renewable energy is available:
Electricity use, by source (percentage of total, 0-100):
Percentage of total electricity use (0-100)
Biomass 0.40
Coal 83.20
Geothermal 0
Hydro 1.60
Natural gas 9.90
Nuclear 0
Solar photovoltaic 3.70
Wind 1
Other (please specify and explain below) 0.20

A brief description of other sources of electricity not specified above:

0.2% imported from NSW (interstate)


Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100)
Biomass ---
Coal ---
Electricity 100
Fuel oil ---
Geothermal ---
Natural gas ---
Other (please specify and explain below) ---

A brief description of other sources of building heating not specified above:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.