OP-3: Building Operations and Maintenance

Status Score Responsible Party
Complete 1.85 / 5.00 Teddy Lhoutellier
Sustainability Manager
Environmental Health and Safety
"---" indicates that no data was submitted for this field

Total floor area of building space:
9,936,736 Square feet

Floor area of building space that is certified at each level under a green building rating system for the operations and maintenance of existing buildings used by an Established Green Building Council:
Certified Floor Area
LEED O+M Platinum or the highest achievable level under another GBC rating system 0 Square feet
LEED O+M Gold or the 2nd highest level under another 4- or 5-tier GBC rating system 0 Square feet
Certified at mid-level under a 3- or 5-tier GBC rating system (e.g. BREEAM-In Use, CASBEE for Existing Buildings, DGNB, Green Star Performance) 0 Square feet
LEED O+M Silver or at a step above minimum level under another 4 -or 5–tier GBC rating system 0 Square feet
LEED O+M Certified or certified at minimum level under another GBC rating system 0 Square feet

Floor area of building space that is certified under a non-GBC rating system for the operations and maintenance of existing buildings, e.g. BOMA BESt, Green Globes CIEB:
674,723.58 Square feet

Percentage of building space certified under a green building rating system for the operations and maintenance of existing buildings:
6.79

A brief description of the green building rating system(s) used and/or a list or sample of certified buildings and ratings:

The Energy Star Rating system ask for each building to use 35% less energy than other similar type of buildings in the US.

Energy Star:
Gables One Tower; Don Soffer Clinical Research Building


Of the institution's uncertified building space, what percentage of floor area is maintained in accordance with a published indoor air quality (IAQ) management policy or protocol? (0-100):
100

A copy of the IAQ management policy or protocol:
The website URL where the IAQ policy/protocol may be found:
Of the institution's uncertified building space, what percentage of floor area is maintained in accordance with a published green cleaning policy, program or contract ? (0-100):
60

A copy or the green cleaning policy:
A brief description of how green cleaning is incorporated into cleaning contracts:

No specific policy for green cleaning, even though our contractor uses its Green Cleaning guidelines in 60% of our buildings


Of the institution's uncertified building space, what percentage of floor area is maintained in accordance with an energy management or benchmarking program? (0-100):
100

A brief description of the energy management or benchmarking program:

A 3-month analysis of Electricity and Natural Gas consumption is done, which is compared to the same period of time (3-months) of the previous year. A threshold of +/-10% is set, and any variances greater of less than this is investigated for their variance drivers.

Specific to the School of Medicine campus:
All buildings are currently supplied with 40-41F chill water that provide indoor air RH levels below 60%. The majority of our facilities are wet lab type facilities with outdoor air (OA) requirements ranging for 60%-100%. Most of the areas require 6 air exchanges driven by laboratory fume hood volumes or vivarium where air exchange rates range between 10 and 12 per hour. At the moment Energy Use Intensity is tracked since 2013 for bench marking purposes. Overall $/ton-hour is tracked at the district cooling facility daily as well as Kw/ton efficiency.


Of the institution's uncertified building space, what percentage of floor area is maintained in accordance with a water management or benchmarking program? (0-100):
100

A brief description of the water management or benchmarking program:

A 3-month analysis of water consumption is done, which is compared to the same period of time (3-months) of the previous year. A threshold of +/-10% is set, and any variances greater of less than this is investigated for their respective variance drivers

Monthly water consumption is tracked using our ECOVA billing platform and notification services. Higher than average consumption is reported to management when meter readings exceed 10% percent above prior years readings.


The website URL where information about the programs or initiatives is available:
Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.