Overall Rating Bronze
Overall Score 29.24
Liaison Laurel Pikcunas
Submission Date March 3, 2022

STARS v2.2

University of Hawaii Windward Community College
OP-6: Clean and Renewable Energy

Status Score Responsible Party
Complete 1.46 / 4.00 Matt Lynch
Director of Sustainability Initiatives
UH Office of Sustainability
"---" indicates that no data was submitted for this field

Total energy consumption, performance year:
11,261.85 MMBtu

Clean and renewable electricity (report kilowatt-hours):
kWh MMBtu
Imported electricity from certified/verified clean and renewable sources (i.e., bundled green power purchases) 0 Kilowatt-hours 0 MMBtu
Electricity from on-site, clean and renewable sources (rights retained/retired) 1,201,260 Kilowatt-hours 4,098.70 MMBtu

A brief description of the certified/verified sources of clean and renewable electricity:
---

A brief description of the on-site renewable electricity generating facilities/devices:

Windward Community College installed Solar Panel shade cover for the majority of the campus's parking areas in 2019, with them coming online late 2019. The PV is coupled with onsite battery storage.

Hale La‘akea also produces energy from its rooftoop solar.


Clean and renewable thermal energy (report MMBtu):
MMBtu
Clean and renewable stationary fuels used on-site to generate thermal energy 0 MMBtu
Imported steam, hot water, and/or chilled water from certified/verified clean and renewable sources 0 MMBtu

A brief description of the clean and renewable stationary fuels:
---

A brief description of the certified/verified sources of clean and renewable thermal energy:

On September 1, Windward CC became the second UH Community College campus to significantly reduce its carbon footprint by generating 70% of its energy through on-site photovoltaic (PV) systems. The 3,125 PV modules installed on the Windward CC campus are capable of generating 1.469 megawatts of power annually, enough to power 177 homes every year, and offsetting greenhouse gas emissions equal to 3,554 barrels of oil a year.


Unbundled renewable energy products (report kWh):
kWh MMBtu
Purchased RECs, GOs, I-RECs or equivalent unbundled renewable energy products certified by a third party 0 Kilowatt-hours 0 MMBtu

A brief description of the unbundled renewable energy products:

WCC purchases energy from HECO. HECO's grid operated with 25.2% renewables.


Total clean and renewable energy generated or purchased:
4,098.70 MMBtu

Percentage of total energy consumption from clean and renewable sources:
36.39

Website URL where information about the institution’s support for clean and renewable energy is available:
Electricity use, by source (percentage of total, 0-100):
Percentage of total electricity use (0-100)
Biomass ---
Coal ---
Geothermal ---
Hydro ---
Natural gas ---
Nuclear ---
Solar photovoltaic 70
Wind ---
Other (please specify and explain below) ---

A brief description of other sources of electricity not specified above:
---

Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100)
Biomass ---
Coal ---
Electricity ---
Fuel oil ---
Geothermal ---
Natural gas ---
Other (please specify and explain below) ---

A brief description of other sources of building heating not specified above:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.