Overall Rating Silver - expired
Overall Score 48.07
Liaison Tony Gillund
Submission Date May 9, 2017
Executive Letter Download

STARS v2.1

The Ohio State University at Lima
OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 1.88 / 10.00 Tony Gillund
Sustainability Manager
Energy Services and Sustainability
"---" indicates that no data was submitted for this field

Part 1 

Has the institution conducted a GHG emissions inventory that includes all Scope 1 and 2 emissions? :
Yes

Does the institution’s GHG emissions inventory include all, some or none of its Scope 3 GHG emissions from the following categories?:
All, Some, or None
Business travel Some
Commuting All
Purchased goods and services None
Capital goods None
Waste generated in operations Some
Fuel- and energy-related activities not included in Scope 1 or Scope 2 Some
Other categories None

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory, including how the institution accounted for each category of Scope 3 emissions reported above:
The data collection for the Ohio State's Carbon Footprint is carried out by employees in the Energy Services and Sustainability Office (ESS). ESS employees contact the various departments within the university that maintain records of data relevant to the Carbon Footprint Inventory. The Clean Air Cool Planet (CACP) Campus Carbon Calculator version 8.0 is used to format the data and calculate the equivalent CO2 emissions from each of the inventoried sources. The Campus Carbon Calculator is updated each year with new emission coefficients and trending equations.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No

A brief description of the internal and/or external verification process:
---

Documentation to support the internal and/or external verification process:
---

Does the institution wish to pursue Part 2 and Part 3 of this credit? (reductions in Scope 1 and Scope 2 GHG emissions):
Yes

Part 2 

Gross Scope 1 and Scope 2 GHG emissions:
Performance Year Baseline Year
Gross Scope 1 GHG emissions from stationary combustion 2,133.90 Metric tons of CO2 equivalent 2,053.56 Metric tons of CO2 equivalent
Gross Scope 1 GHG emissions from other sources 67.40 Metric tons of CO2 equivalent 29.54 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from purchased electricity 6,343.80 Metric tons of CO2 equivalent 6,181.90 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Total 8,545.10 Metric tons of CO2 equivalent 8,265 Metric tons of CO2 equivalent

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year July 1, 2016 June 30, 2017
Baseline Year July 1, 2015 June 30, 2016

A brief description of when and why the GHG emissions baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):
---

Figures needed to determine total carbon offsets:
Performance Year Baseline Year
Third-party verified carbon offsets purchased (exclude purchased RECs/GOs) 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon offsets included above for which the emissions reductions have been sold or transferred by the institution 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Net carbon offsets 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

If total performance year carbon offsets are greater than zero, provide:

A brief description of the offsets in each category reported above, including vendor, project source, verification program and contract timeframes (as applicable):
---

The reporting fields in the table below are reserved for institutions that have NOT already accounted for renewable energy purchases (including RECs and GOs) in their Scope 2 GHG emissions calculations. Other institutions - including all SIMAP users - should report zero ('0') to avoid double-counting. 

Emissions reductions attributable to Renewable Energy Certificate (REC) or Guarantee of Origin (GO) purchases:
Performance Year Baseline Year
Emissions reductions attributable to REC/GO purchases 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the purchased RECs/GOs including vendor, project source and verification program:
---

Adjusted net Scope 1 and 2 GHG emissions:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions 8,545.10 Metric tons of CO2 equivalent 8,265 Metric tons of CO2 equivalent

Figures needed to determine “Weighted Campus Users”:
Performance Year Baseline Year
Number of students resident on-site 0 0
Number of employees resident on-site 0 0
Number of other individuals resident on-site and/or staffed hospital beds 0 0
Total full-time equivalent student enrollment 901.79 946.82
Full-time equivalent of employees (staff + faculty) 126 129.61
Full-time equivalent of students enrolled exclusively in distance education 76.60 54
Weighted campus users 713.39 766.82

Adjusted net Scope 1 and 2 GHG emissions per weighted campus user:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user 11.98 Metric tons of CO2 equivalent 10.78 Metric tons of CO2 equivalent

Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
0

Part 3

Gross floor area of building space, performance year:
462,103 Gross square feet

Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 16,665 Square feet
Healthcare space 0 Square feet
Other energy intensive space 0 Square feet

EUI-adjusted floor area, performance year:
495,433 Gross square feet

Adjusted net Scope 1 and 2 GHG emissions per unit of EUI-adjusted floor area, performance year:
0.02 MtCO2e per square foot

Optional Fields 

Scope 3 GHG emissions, performance year:
Emissions
Business travel ---
Commuting ---
Purchased goods and services ---
Capital goods ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 ---
Waste generated in operations ---
Other categories ---

A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
---

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.