Part 1. Greenhouse gas emissions inventory

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
Calculate the ACG greenhouse gas emissions which are classified into Scope 1 and 2 (according to the leading GHG Protocol corporate standard). The calculation is based on the sum of the resources consumption and the relevant GHG emission/
removal factor published by the national bodies (Ministry of the Environment & Energy and Renewable Energy Sources Operator & Guarantees of Origin S.A. DAPEEP, Greece)for the CO2.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the GHG inventory verification process:
Data was analyzed and checked by an independent external engineer and TUV Hellas during ISO50001 audit. The staff involved with the accounting process were interviewed as were key personnel from the Technical Services of the institution.Data was crosschecked with electricity and natural gas bills, purchasing orders and equipment accounted for by the GhG inventory were surveyed. Working assumptions were valid as was the methodology used for the inventory.

Documentation to support the GHG inventory verification process:
Scope 1 GHG emissions
Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 766.65 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 16.50 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
783.15 Metric tons of CO2 equivalent

Scope 2 GHG emissions
Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 1,602.31 Metric tons of CO2 equivalent
Imported thermal energy 0 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
1,602.31 Metric tons of CO2 equivalent

GHG emissions from biomass combustion
Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Scope 3 GHG emissions
Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel Yes 22.87 Metric tons of CO2 equivalent
Commuting No 1,272.89 Metric tons of CO2 equivalent
Purchased goods and services --- ---
Capital goods --- ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 --- ---
Waste generated in operations --- ---
Other sources --- ---

Total Scope 3 GHG emissions, performance year:
1,295.76 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:
---

Part 2. Air pollutant emissions inventory

Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
No

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) ---
Sulfur oxides (SOx) ---
Carbon monoxide (CO) ---
Particulate matter (PM) ---
Ozone (O3) ---
Lead (Pb) ---
Hazardous air pollutants (HAPs) ---
Ozone-depleting compounds (ODCs) ---
Other standard categories of air emissions identified in permits and/or regulations ---

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources ---
Area sources ---
Mobile sources ---
Commuting ---
Off-site electricity production ---

None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
---

Optional Fields

Gross Scope 2 GHG emissions from purchased electricity (location-based):
---

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---

Website URL where information about the institution’s emissions inventories is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
we are in process of certifying ACG greenhouse gas emissions and removals reporting according to ISO 14064-1:2018 standard on July 2023

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.