Overall Rating Silver
Overall Score 46.23
Liaison Martín Sánchez Gutiérrez
Submission Date June 29, 2024

STARS v3.0

Tecnológico de Monterrey – Campus Chihuahua
OP-6: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 10.56 / 16.00
"---" indicates that no data was submitted for this field

6.1 Greenhouse gas emissions inventory and disclosure

Scope 1 and 2 GHG emissions inventory
Has the institution completed an inventory within the previous three years to quantify its scope 1 and scope 2 GHG emissions?:
Yes

Copy of the institution’s GHG emissions inventory:
Online location of the institution’s GHG emissions inventory:
---

Performance year for scope 1 and 2 GHG emissions:
2022

Description of the methodology or calculator used to conduct the scope 1 and 2 GHG emissions inventory:

Our National Greenhouse Gas (GHG) Emissions Report , which is published annually, strictly adheres to the Greenhouse Gas Protocol (GHG Protocol) and the Annual Operation Certificate (COA) required by the Ministry of Environment and Natural Resources in Mexico(SEMARNAT).


Scope 1 GHG emissions

If claiming points for a scope 1 and scope 2 GHG inventory, the following information is required:

Scope 1 GHG emissions from stationary combustion:
75 Metric tons of CO2 equivalent

Scope 1 GHG emissions from mobile combustion:
19 Metric tons of CO2 equivalent

Scope 1 GHG process emissions:
0 Metric tons of CO2 equivalent

Scope 1 GHG fugitive emissions:
85 Metric tons of CO2 equivalent

Scope 2 GHG emissions

If claiming points for a scope 1 and scope 2 GHG inventory, the following information is required:

Which of the following methods were used to quantify the institution’s scope 2 GHG emissions?:
Location-based

Scope 2 GHG emissions from off-site sources of electricity (market-based):
---

If using a location-based or dual reporting method, the following field is also required:

Scope 2 GHG emissions from off-site sources of electricity (location-based):
385 Metric tons of CO2 equivalent

Scope 2 GHG emissions from off-site sources of heating and cooling:
0 Metric tons of CO2 equivalent

The Reporting Tool will automatically calculate the following figure:

Annual scope 1 and 2 GHG emissions:
564 Metric tons of CO2 equivalent

Biogenic emissions 

If claiming points for a scope 1 and scope 2 GHG inventory, the following information is required: 

Does the institution’s GHG emissions accounting method separate out biogenic emissions for disclosure purposes?:
No

GHG emissions from biogenic sources:
---

Scope 3 GHG emissions
Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from business travel?:
Full accounting

Scope 3 GHG emissions from business travel:
---

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from commuting?:
Not at all

Scope 3 GHG emissions from commuting:
185 Metric tons of CO2 equivalent

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from purchased goods and services?:
Not at all

Scope 3 GHG emissions from purchased goods and services:
---

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from capital goods?:
Not at all

Scope 3 GHG emissions from capital goods:
---

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from fuel- and energy-related activities not included in scope 1 or scope 2?:
Not at all

Scope 3 GHG emissions from fuel- and energy-related activities not included in scope 1 or scope 2:
---

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from upstream transportation and distribution?:
Not at all

Scope 3 GHG emissions from upstream transportation and distribution:
---

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions from waste generated in operations?:
Not at all

Scope 3 GHG emissions from waste generated in operations:
---

Within the previous three years, to what extent has the institution quantified its scope 3 GHG emissions in all other applicable categories identified in the GHG Protocol Scope 3 Standard?:
Not at all

Scope 3 GHG emissions from other applicable categories identified in the GHG Protocol Scope 3 Standard:
---

If any scope 3 activities have been quantified, the following field is also required:

Description of the methodologies used to identify and account for the institution’s relevant scope 3 activities:

In 2023 we completed our first national Scope 3 Emissions Screening following the GHG Protocol. However, being a nationwide effort the figures reported above cover all operations from all the Campuses at Tec de Monterrey. We calculate only business travel category per campus. At this time we do not have a full Scope 3 Emissions screening per Campus.


The Reporting Tool will automatically calculate the following figure:

Points earned for indicator OP 6.1:
1.50

6.2 Greenhouse gas emissions per square meter

Peer group:
Baccalaureate colleges and boarding schools

Gross floor area of building space:
51,544.72 Square meters

The Reporting Tool will automatically calculate the following two figures:

Annual scope 1 and 2 GHG emissions per unit of floor area:
10.94 Kilograms per square meter

Points earned for indicator OP 6.2:
3.67

6.3 Greenhouse gas emissions per person

Full-time equivalent student enrollment:
1,259

Full-time equivalent of employees:
355

The Reporting Tool will automatically calculate the following three figures:

Full-time equivalent students and employees:
1,614

Annual scope 1 and 2 GHG emissions per person:
349.44 Kilograms of CO2 equivalent

Points earned for indicator OP 6.3:
3.81

6.4 Adjusted net greenhouse gas emissions

Carbon sinks

Report figures for the performance year. If claiming points for a scope 1 and scope 2 GHG inventory, the following information is required. Non-additional sequestration does not qualify as a carbon sink for scoring purposes, but may be reported in the optional field provided. 

Third party certified carbon offsets:
0 Metric tons of CO2 equivalent

Description of the institution’s third party certified carbon offsets:
---

Carbon storage from on-site composting:
0 Metric tons of CO2 equivalent

Description of the institution’s carbon storage from on-site composting:
---

Carbon sold or transferred:
0 Metric tons of CO2 equivalent

Carbon storage from non-additional sequestration on institution-owned land:
10 Metric tons of CO2 equivalent

Baseline emissions
Does the institution have baseline scope 1 and 2 GHG emissions data?:
Yes

Copy of the institution’s baseline GHG emissions inventory:
---

Online location of the institution’s baseline GHG emissions inventory:
Baseline year for scope 1 and 2 GHG emissions:
2019

Narrative outlining when and why the GHG emissions baseline was adopted:

2019 was the last year of pre-pandemic operations in our Campuses. 2019 was the national baseline adopted for all campuses in Tec system in order to make sure that post-pandemic electricity and fuel consumption does not goes anywhere near 2019's baseline (2019 was the year of most energy, water and resources consumed in the history of the institution)


Baseline scope 1 and 2 GHG emissions:
935 Metric tons of CO2 equivalent

The Reporting Tool will automatically calculate the following four figures:

Net carbon sinks:
0 Metric tons of CO2 equivalent

Adjusted net scope 1 and 2 GHG emissions:
564 Metric tons of CO2 equivalent

Percentage reduction in scope 1 and 2 GHG emissions from baseline:
39.68

Points earned for indicator OP 6.4:
1.59

Optional documentation

Notes about the information provided for this credit:
---

Additional documentation for this credit:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.