Overall Rating | Silver |
---|---|
Overall Score | 53.71 |
Liaison | Andrea Bradley |
Submission Date | Nov. 28, 2023 |
TAFE Queensland Robina Campus
OP-2: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
1.80 / 8.00 |
George
Anderson Director, Property & Facilities TQGC |
"---"
indicates that no data was submitted for this field
Scope 1 and Scope 2 GHG emissions
Gross GHG emissions
Performance year | Baseline year | |
Gross Scope 1 GHG emissions from stationary combustion | 236.20 Metric tons of CO2 equivalent | 236.20 Metric tons of CO2 equivalent |
Gross Scope 1 GHG emissions from other sources | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported electricity | 900.45 Metric tons of CO2 equivalent | 900.45 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported thermal energy | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Total | 1,136.65 Metric tons of CO2 equivalent | 1,136.65 Metric tons of CO2 equivalent |
Carbon sinks
Performance year | Baseline year | |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from non-additional sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon sold or transferred | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Net carbon sinks | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
If total performance year carbon sinks are greater than zero, provide:
Not applicable
Adjusted net GHG emissions
Performance year | Baseline year | |
Adjusted net GHG emissions | 1,136.65 Metric tons of CO2 equivalent | 1,136.65 Metric tons of CO2 equivalent |
Performance and baseline periods
Performance year | Baseline year | |
Start date | July 1, 2022 | July 1, 2022 |
End date | June 30, 2023 | June 30, 2023 |
A brief description of when and why the GHG emissions baseline was adopted:
Robina Campus is a newly built campus and became operational in July 2022. As a result, we are currently collecting baseline data for the first year of full operations 1 July 2022 - 30 June 2023. As we have only been operational for one full financial year, the baseline year and the performance year use the same data.
Part 1. Reduction in GHG emissions per person
Weighted campus users
Performance year | Baseline year | |
Number of students resident on-site | 0 | 0 |
Number of employees resident on-site | 0 | 0 |
Number of other individuals resident on-site | 0 | 0 |
Total full-time equivalent student enrollment | 1,608 | 1,608 |
Full-time equivalent of employees | 101 | 101 |
Full-time equivalent of students enrolled exclusively in distance education | 0 | 0 |
Weighted Campus Users | 1,281.75 | 1,281.75 |
Metrics used in scoring for Part 1
Performance year | Baseline year | |
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user | 0.89 Metric tons of CO2 equivalent | 0.89 Metric tons of CO2 equivalent |
Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
0
Part 2. GHG emissions per unit of floor area
Performance year floor area
8,055
Gross square meters
Floor area of energy intensive building space, performance year:
Floor area | |
Laboratory space | 0 Square meters |
Healthcare space | 0 Square meters |
Other energy intensive space | 1,555 Square meters |
EUI-adjusted floor area, performance year:
9,610
Gross square meters
Metric used in scoring for Part 2
0.12
MtCO2e per square meter
A brief description of the institution’s GHG emissions reduction initiatives:
Utilising the Building Management system to adjust mechanical Variable Speed Drive (VSD), isolating mechanical operation by room against usage. Lighting controls through automated ZEN software to reduce lighting levels and usage. 99kW Solar System offsetting imported energy through energy production to the building and returning energy to the grid.
Statistics on usage and monthly tracking of current performance against sustainability targets are being monitored using a Building Management System (BMS) with a comprehensive Bi report tracking progress. The BMS has significant capabilities including separate metering lighting general power and mechanical services. The lighting system interfaces with the BMS and controls the HVAC (heating, ventilation, and air conditioning). The Bi report produces visuals that can be used to connect to the community using factors such as trees planted.
Statistics on usage and monthly tracking of current performance against sustainability targets are being monitored using a Building Management System (BMS) with a comprehensive Bi report tracking progress. The BMS has significant capabilities including separate metering lighting general power and mechanical services. The lighting system interfaces with the BMS and controls the HVAC (heating, ventilation, and air conditioning). The Bi report produces visuals that can be used to connect to the community using factors such as trees planted.
Website URL where information about the institution's GHG emissions is available:
---
Additional documentation to support the submission:
Data source(s) and notes about the submission:
Image of Robina Campus building attached.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.