Overall Rating Platinum
Overall Score 86.83
Liaison Mark Lichtenstein
Submission Date Feb. 28, 2023

STARS v2.2

State University of New York College of Environmental Science and Forestry
OP-21: Water Use

Status Score Responsible Party
Complete 4.00 / 4.00 Michael Amadori
Campus Energy Manager
Office of Sustainable Facilities and Operations
"---" indicates that no data was submitted for this field

Level of ”Physical Risk Quantity” for the institution’s main campus as indicated by the World Resources Institute Aqueduct Water Risk Atlas:
Low

Total water withdrawal (potable and non-potable combined):
Performance Year Baseline Year
Total water withdrawal 15,271,900 Gallons 26,251,000 Gallons

Potable water use:
Performance Year Baseline Year
Potable water use 14,313,633 Gallons 26,251,000 Gallons

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Period July 1, 2021 June 30, 2022
Baseline Period July 1, 2006 June 30, 2007

A brief description of when and why the water use baseline was adopted:

The baseline is aligned with the carbon neutral and energy reduction 2007 baseline. Since 2007, the square footage has increased and the Syracuse campus food service has been added to water usage.


Figures needed to determine "Weighted Campus Users":
Performance Year Baseline Year
Number of students resident on-site 595 0
Number of employees resident on-site 25 0
Number of other individuals resident on-site 12 0
Total full-time equivalent student enrollment 1,889.18 1,955
Full-time equivalent of employees 520.76 540
Full-time equivalent of students enrolled exclusively in distance education 31.31 0
Weighted campus users 1,950.97 1,871.25

Potable water use per weighted campus user:
Performance Year Baseline Year
Potable water use per weighted campus user 7,336.67 Gallons 14,028.59 Gallons

Percentage reduction in potable water use per weighted campus user from baseline:
47.70

Gross floor area of building space:
Performance Year Baseline Year
Gross floor area 1,188,325 Gross square feet 1,049,203 Gross square feet

Potable water use per unit of floor area:
Performance Year Baseline Year
Potable water use per unit of floor area 12.05 Gallons per square foot 25.02 Gallons per square foot

Percentage reduction in potable water use per unit of floor area from baseline:
51.86

Area of vegetated grounds:
Performance Year Baseline Year
Vegetated grounds 6.75 Acres 6.75 Acres

Total water withdrawal per unit of vegetated grounds:
Performance Year Baseline Year
Total water withdrawal per unit of vegetated grounds 2,262,503.70 Gallons per acre 3,889,037.04 Gallons per acre

Percentage reduction in total water withdrawal per unit of vegetated grounds from baseline:
41.82

A brief description of the institution's water-related behavior change initiatives:
---

A brief description of the institution's water recovery and reuse initiatives:

Non-potable water running off the Baker Hall roof is captured by leaders (gutters) and is stored in large tanks in the building basement. This water is then used to wash college vehicles.


A brief description of the institution's initiatives to replace plumbing fixtures, fittings, appliances, equipment, and systems with water-efficient alternatives:

Since 2007, ESF has been installing water-efficient faucets and toilets. Facilities staff has improved operational water use efficiency and mitigated numerous leaks in recent years. The volume of ESF water use also fluctuates from year to year based on research and operational activities on the Syracuse and regional campuses.

ESF also installed building level water meters on all of it's building and connected the meters to Lucid Building OS dashboard to more monitor water use in more granular detail. This has allowed for additional identification and mitigation of leaks and inefficiencies.

https://buildingos.com/s/SUNYESF/storyboard10913/?chapterId=63013

ESF commissioned a free cooling chiller that uses ambient air temperatures to cool condenser water and allows Baker Labs to avoid running the air conditioning during after hours, weekends, and holidays. This system reduces water consumption in a water cooled chiller as well cooling tower make-up water.


Website URL where information about the institution’s water conservation and efficiency efforts is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.