Overall Rating Bronze
Overall Score 38.48
Liaison Jesse Carswell
Submission Date June 27, 2023

STARS v2.2

Southern New Hampshire University
OP-1: Emissions Inventory and Disclosure

Status Score Responsible Party
Complete 2.46 / 3.00
"---" indicates that no data was submitted for this field

Part 1. Greenhouse gas emissions inventory

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
The emissions inventory was conducted using the UNH SIMAP tool. Data sources included: Utility bills for electricity, natural gas, and other fuels. Vendor bills were used for fertilizer.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the GHG inventory verification process:
SIMAP data was reviewed and audited by the SIMAP reporting team in May 2023. They
performed an audit to identify gaps or potential inaccuracies.

Documentation to support the GHG inventory verification process:
Scope 1 GHG emissions
Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 3,367.42 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 74.22 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
3,441.64 Metric tons of CO2 equivalent

Scope 2 GHG emissions
Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 6,425.23 Metric tons of CO2 equivalent
Imported thermal energy 0 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
6,425.23 Metric tons of CO2 equivalent

GHG emissions from biomass combustion
Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Scope 3 GHG emissions
Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel Yes 1,041.55 Metric tons of CO2 equivalent
Commuting Yes 6,842.62 Metric tons of CO2 equivalent
Purchased goods and services No ---
Capital goods No ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 Yes 359.60 Metric tons of CO2 equivalent
Waste generated in operations No ---
Other sources Yes 359.60 Metric tons of CO2 equivalent

Total Scope 3 GHG emissions, performance year:
8,603.37 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:
---

Part 2. Air pollutant emissions inventory

Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
Yes

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) 0.10 Tons
Sulfur oxides (SOx) 0.00 Tons
Carbon monoxide (CO) 0.01 Tons
Particulate matter (PM) 0.00 Tons
Ozone (O3) 0 Tons
Lead (Pb) 0 Tons
Hazardous air pollutants (HAPs) 0 Tons
Ozone-depleting compounds (ODCs) 0 Tons
Other standard categories of air emissions identified in permits and/or regulations 0 Tons

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources Yes
Area sources No
Mobile sources No
Commuting No
Off-site electricity production No

None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
Report generated New Hampshire Department of Environmental Services

Optional Fields

Gross Scope 2 GHG emissions from purchased electricity (location-based):
---

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---

Website URL where information about the institution’s emissions inventories is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.