Overall Rating Silver
Overall Score 61.84
Liaison Carolyn Shafer
Submission Date March 4, 2022

STARS v2.2

Pratt Institute
OP-6: Clean and Renewable Energy

Status Score Responsible Party
Complete 0.01 / 4.00 Tony Gelber
Dir. Admin. Sustainability
Facilities/Sustainability
"---" indicates that no data was submitted for this field

Total energy consumption, performance year:
148,563.55 MMBtu

Clean and renewable electricity (report kilowatt-hours):
kWh MMBtu
Imported electricity from certified/verified clean and renewable sources (i.e., bundled green power purchases) 0 Kilowatt-hours 0 MMBtu
Electricity from on-site, clean and renewable sources (rights retained/retired) 25,000 Kilowatt-hours 85.30 MMBtu

A brief description of the certified/verified sources of clean and renewable electricity:
---

A brief description of the on-site renewable electricity generating facilities/devices:

Pratt has a 25KW solar array on site producing electricity.
We retain the credits.


Clean and renewable thermal energy (report MMBtu):
MMBtu
Clean and renewable stationary fuels used on-site to generate thermal energy 238 MMBtu
Imported steam, hot water, and/or chilled water from certified/verified clean and renewable sources 0 MMBtu

A brief description of the clean and renewable stationary fuels:

Pratt uses 5% biodiesel in the Central Plant.


A brief description of the certified/verified sources of clean and renewable thermal energy:
---

Unbundled renewable energy products (report kWh):
kWh MMBtu
Purchased RECs, GOs, I-RECs or equivalent unbundled renewable energy products certified by a third party 0 Kilowatt-hours 0 MMBtu

A brief description of the unbundled renewable energy products:
---

Total clean and renewable energy generated or purchased:
323.30 MMBtu

Percentage of total energy consumption from clean and renewable sources:
0.22

Website URL where information about the institution’s support for clean and renewable energy is available:
---

Electricity use, by source (percentage of total, 0-100):
Percentage of total electricity use (0-100)
Biomass ---
Coal ---
Geothermal ---
Hydro 18
Natural gas ---
Nuclear 32
Solar photovoltaic 2.50
Wind 3
Other (please specify and explain below) ---

A brief description of other sources of electricity not specified above:

Source for above US EIA 2014.


Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100)
Biomass 0
Coal 0
Electricity 0.00
Fuel oil 5
Geothermal 0
Natural gas 94
Other (please specify and explain below) 0.00

A brief description of other sources of building heating not specified above:

Biodiesel


Additional documentation to support the submission:
Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.