Overall Rating | Gold - expired |
---|---|
Overall Score | 72.23 |
Liaison | Brandon Trelstad |
Submission Date | Jan. 31, 2018 |
Executive Letter | Download |
Oregon State University
OP-4: Building Design and Construction
Status | Score | Responsible Party |
---|---|---|
1.25 / 3.00 |
Brandon
Trelstad Sustainability Coordinator Sustainability Office |
"---"
indicates that no data was submitted for this field
Total floor area of newly constructed or renovated building space (include projects completed within the previous five years) :
975.48
Square meters
Certified Projects
0
Square meters
Floor area of newly constructed or renovated building space certified at each level under a rating system for design and construction used by an Established Green Building Council (GBC) :
Certified Floor Area | |
LEED BD+C Platinum or at the highest achievable level under another rating system | 0 Square meters |
LEED BD+C Gold or at the 2nd highest level under another 4- or 5-tier GBC rating system | 0 Square meters |
Certified at mid-level under a 3- or 5-tier GBC rating system for design and construction (e.g. BREEAM, CASBEE, DGNB, Green Star) | 0 Square meters |
LEED BD+C Silver or at a step above minimum level under another 4- or 5-tier GBC rating system | 0 Square meters |
LEED BD+C Certified or certified at minimum level under another GBC rating system | 0 Square meters |
Floor area of newly constructed or renovated building space certified under a non-GBC rating system for design and construction (e.g. Green Globes NC, Certified Passive House):
0
Square meters
Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
0
If reporting certified projects, provide:
OSU typically designs and builds to LEED Silver equivalence, or better, for all projects.
If reporting uncertified projects, provide:
Uncertified Projects
975.48
Square meters
If reporting published green building guidelines or policies, provide the following:
---
The green building guidelines or policies:
OSU's equivalency standard for this project was LEED 2009 for New Construction and Major Renovation. Although full certification was not sought, the scorecard and process was followed by OSU and the design team. For more information: http://fa.oregonstate.edu/sustainability/operations/green-building/completed-construction
Do the green building guidelines or policies cover the following?:
Yes or No | |
Impacts on the surrounding site (e.g. guidelines to reuse previously developed land, protect environmentally sensitive areas, and otherwise minimize site impacts) | Yes |
Energy consumption (e.g. policies requiring a minimum level of energy efficiency for buildings and their systems) | Yes |
Building-level energy metering | Yes |
Use of environmentally preferable materials (e.g. guidelines to minimize the life cycle impacts associated with building materials) | Yes |
Indoor environmental quality (i.e. guidelines to protect the health and comfort of building occupants) | Yes |
Water consumption (e.g. requiring minimum standards of efficiency for indoor and outdoor water use) | Yes |
Building-level water metering | Yes |
A brief description of the green building guidelines or policies and/or a list or sample of buildings covered:
An updated complete list of OSU's green buildings is located at http://fa.oregonstate.edu/sustainability/operations/green-building/completed-construction
None
A brief description of how the institution ensures compliance with green building design and construction guidelines and policies:
Internal review by the OSU Sustainability Office, in partnership with Capital Planning and Facilities, verifies compliance with OSU's LEED equivalent requirement. Additionally, results are published at a publicly accessible site at: http://fa.oregonstate.edu/sustainability/operations/green-building/completed-construction.
Optional Fields
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
Data for Johnson Hall was not provided by OSU project manager by the time of STARS submission. Data reported here reflects Precision Agricultural Systems Center, mostly constructed as a tenant improvement (TI) project to be fit-out at a later date/time.
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.