Overall Rating Gold
Overall Score 71.89
Liaison Isabel Savransky
Submission Date Nov. 14, 2023

STARS v2.2

Ontario Tech University
OP-1: Emissions Inventory and Disclosure

Status Score Responsible Party
Complete 1.67 / 3.00 Isabel Savransky
Sustainability & Asset Planner
Office of Campus Infrastructure and Sustainability
"---" indicates that no data was submitted for this field

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:

Building consumption is entered into the Ministry of Energy webform and calculated as per a GHG formula. Scope 1 and Scope 2 are reported directly from utility bills and consumption reports. We also enter tis data into SIMAP going back to 2011.

Scope 3: Data for commuting and business travel was collected a 2023 survey to staff, faculty and students by Professors Shilpa and Dan; as well as specific data collected from departments (outlining business and research related travel)


Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No

A brief description of the GHG inventory verification process:
---

Documentation to support the GHG inventory verification process:
---

Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 2,484.97 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 191.44 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
2,676.41 Metric tons of CO2 equivalent

Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 703.67 Metric tons of CO2 equivalent
Imported thermal energy 13.74 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
717.41 Metric tons of CO2 equivalent

Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel Yes 3.44 Metric tons of CO2 equivalent
Commuting Yes 72.78 Metric tons of CO2 equivalent
Purchased goods and services No ---
Capital goods --- ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 Yes 954.68 Metric tons of CO2 equivalent
Waste generated in operations Yes 6.88 Metric tons of CO2 equivalent
Other sources No ---

Total Scope 3 GHG emissions, performance year:
1,037.78 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:

Data collected via surveys (for commuting), and via concur for business travel. This data is input into SIMAP (Sustainability Indicator Management & Analysis Platform).


Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
No

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) 0 Metric tons
Sulfur oxides (SOx) 0 Metric tons
Carbon monoxide (CO) 0 Metric tons
Particulate matter (PM) 0 Metric tons
Ozone (O3) 0 Metric tons
Lead (Pb) 0 Metric tons
Hazardous air pollutants (HAPs) 0 Metric tons
Ozone-depleting compounds (ODCs) 0 Metric tons
Other standard categories of air emissions identified in permits and/or regulations 0 Metric tons

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources ---
Area sources ---
Mobile sources ---
Commuting ---
Off-site electricity production ---

A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
---

Gross Scope 2 GHG emissions from purchased electricity (location-based):
---

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---

Website URL where information about the institution’s emissions inventories is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.