Overall Rating Gold - expired
Overall Score 74.96
Liaison Megan Butler
Submission Date Jan. 19, 2021

STARS v2.2

Macalester College
OP-1: Emissions Inventory and Disclosure

Status Score Responsible Party
Complete 2.35 / 3.00 Mike Pumroy
Energy Manager
Facilities Services
"---" indicates that no data was submitted for this field

Part 1. Greenhouse gas emissions inventory

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
First, we use kWh360 as a tool to track our utility bills directly. We then copy and enter the utility bill information into Energy Star, a widely used system run by the United States EPA, which can perform several different analyses on our data, including calculating our GHG emissions.
Lastly, we used Figbytes to track our Scope 3 emissions, such as for our study away airline flights.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the GHG inventory verification process:
Macalester's Facilities Services collects and inputs the utility bill data into kWh360 and EnergyStar. The Sustainability Office then has access to each of these systems to run our own analyses.

Documentation to support the GHG inventory verification process:
---

Scope 1 GHG emissions
Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 5,438.50 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 0 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
5,438.50 Metric tons of CO2 equivalent

Scope 2 GHG emissions
Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 5,923.70 Metric tons of CO2 equivalent
Imported thermal energy 0 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
5,923.70 Metric tons of CO2 equivalent

GHG emissions from biomass combustion
Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Scope 3 GHG emissions
Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel Yes 1,871.70 Metric tons of CO2 equivalent
Commuting Yes 327.10 Metric tons of CO2 equivalent
Purchased goods and services No 0 Metric tons of CO2 equivalent
Capital goods No 0 Metric tons of CO2 equivalent
Fuel- and energy-related activities not included in Scope 1 or Scope 2 No 0 Metric tons of CO2 equivalent
Waste generated in operations Yes 80.10 Metric tons of CO2 equivalent
Other sources No 0 Metric tons of CO2 equivalent

Total Scope 3 GHG emissions, performance year:
2,278.90 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:
The Sustainability uses Figbytes, a data manager that tracks Scope 3 inputs and outputs their emissions.

Part 2. Air pollutant emissions inventory

Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
Yes

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) 3.51 Tons
Sulfur oxides (SOx) 0.04 Tons
Carbon monoxide (CO) 0.52 Tons
Particulate matter (PM) 0.04 Tons
Ozone (O3) 0 Tons
Lead (Pb) 0 Tons
Hazardous air pollutants (HAPs) 0 Tons
Ozone-depleting compounds (ODCs) 0 Tons
Other standard categories of air emissions identified in permits and/or regulations 0.11 Tons

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources Yes
Area sources No
Mobile sources No
Commuting No
Off-site electricity production No

None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
We track the amount and type of fuel used to generate steam from the boilers in the central heating plant, along with an estimate of the fuel used to produce electricity from our emergency generators (based on number of hours run). These figures are submitted to the state and used to calculate a fee based on our portion of the various pollutants associated with these fuels. The estimated amounts the state determines we have contributed are indicated here.

Optional Fields

Gross Scope 2 GHG emissions from purchased electricity (location-based):
---

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---

Website URL where information about the institution’s emissions inventories is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.