Overall Rating | Gold |
---|---|
Overall Score | 75.28 |
Liaison | Kara Holmstrom |
Submission Date | Feb. 25, 2022 |
Luther College
OP-1: Emissions Inventory and Disclosure
Status | Score | Responsible Party |
---|---|---|
1.94 / 3.00 |
Jay
Uthoff Director of Facilities Facilities Management |
"---"
indicates that no data was submitted for this field
Part 1. Greenhouse gas emissions inventory
Yes
A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
The University of New Hampshire's Sustainability Institutes SIMAP tool was used to calculate emissions. We used the default emissions coefficients provided by this tool in our calculations. There are supporting documents for each of the categories directly paid by Luther College. These expenses are reconciled to the College's audited financial statements. The units associated with carbon amounts were collected from these detailed expenditures and totaled for each carbon category. The emissions resulting from rented property for the Nurses in Rochester, MN and in Nottingham, England represent less than .3 of 1% of the total college owned properties, and it would not be practical to obtain these emissions as the utilities figures are not provided or paid by Luther, so these sources were left out.
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No
A brief description of the GHG inventory verification process:
---
Documentation to support the GHG inventory verification process:
---
Scope 1 GHG emissions
Weight in MTCO2e | |
Stationary combustion | 5,329.50 Metric tons of CO2 equivalent |
Other sources (mobile combustion, process emissions, fugitive emissions) | 160.73 Metric tons of CO2 equivalent |
Total gross Scope 1 GHG emissions, performance year:
5,490.23
Metric tons of CO2 equivalent
Scope 2 GHG emissions
Weight in MTCO2e | |
Imported electricity | 3,413.80 Metric tons of CO2 equivalent |
Imported thermal energy | 0 Metric tons of CO2 equivalent |
Total gross Scope 2 GHG emissions, performance year:
3,413.80
Metric tons of CO2 equivalent
GHG emissions from biomass combustion
0
Metric tons of CO2 equivalent
Scope 3 GHG emissions
Yes or No | Weight in MTCO2e | |
Business travel | Yes | 40.10 Metric tons of CO2 equivalent |
Commuting | Yes | 443.73 Metric tons of CO2 equivalent |
Purchased goods and services | No | 0 Metric tons of CO2 equivalent |
Capital goods | No | 0 Metric tons of CO2 equivalent |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | Yes | 309.84 Metric tons of CO2 equivalent |
Waste generated in operations | Yes | 385 Metric tons of CO2 equivalent |
Other sources | Yes | 12.64 Metric tons of CO2 equivalent |
Total Scope 3 GHG emissions, performance year:
1,191.31
Metric tons of CO2 equivalent
A brief description of how the institution accounted for its Scope 3 emissions:
Luther College tracks our air travel used for business purposes, as well as our landfilled waste, wastewater treatment, and calculates commuting. The 12.64 MT of "Other sources" is from wastewater treatment.
Part 2. Air pollutant emissions inventory
Yes
Annual weight of emissions for::
Weight of Emissions | |
Nitrogen oxides (NOx) | 2.58 Tons |
Sulfur oxides (SOx) | 0.02 Tons |
Carbon monoxide (CO) | 3.72 Tons |
Particulate matter (PM) | 0.34 Tons |
Ozone (O3) | --- |
Lead (Pb) | --- |
Hazardous air pollutants (HAPs) | --- |
Ozone-depleting compounds (ODCs) | --- |
Other standard categories of air emissions identified in permits and/or regulations | --- |
Do the air pollutant emissions figures provided include the following sources?:
Yes or No | |
Major stationary sources | Yes |
Area sources | No |
Mobile sources | No |
Commuting | No |
Off-site electricity production | No |
None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
We input our boiler operational information in the State of Iowa State and Local Emissions Inventory System (SLEIS) and use the information derived from that system to report.
Optional Fields
6,229
Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
---
Website URL where information about the institution’s emissions inventories is available:
---
Additional documentation to support the submission:
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.