Overall Rating Gold
Overall Score 79.77
Liaison Josh Lasky
Submission Date April 4, 2023

STARS v2.2

George Washington University
OP-3: Building Design and Construction

Status Score Responsible Party
Complete 2.19 / 3.00 Brian Snyder
Senior Director | Campus Planning
Facilities Planning, Construction and Management
"---" indicates that no data was submitted for this field

Total floor area of newly constructed or renovated building space:
268,693 Square feet

Floor area of eligible building space designed and built in accordance with published green building codes, policies, and/or rating systems:
Floor area
Certified at the highest achievable level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Platinum or Certified Living Building) 0 Square feet
Certified at the 2nd highest level under a 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Gold) 207,820 Square feet
Certified at mid-level under a 3- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., BREEAM Very Good) 0 Square feet
Certified at a step above minimum level under ar 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Silver) 0 Square feet
Certified at minimum level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Certified) 0 Square feet
Certified/verified at any level under a multi-attribute, non-GBC rating system for design and construction, a green building code, or a single-attribute rating system for design and construction 0 Square feet
Designed and built in accordance with a multi-attribute green building code, policy, guideline, or rating system, but not certified/verified 55,220 Square feet
Designed and built in accordance with a single-attribute green building code, policy, guideline, or rating system, but not certified/verified 0 Square feet
Total 263,040 Square feet

Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
77.34

A list of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
1 South Hall 2010 NC GOLD 214,346
2 West Hall 2010 NC GOLD 139,591
3 Lafayette Hall 2012 NC GOLD 36,035
4 Smith Center 2012 NC GOLD 129,302
5 Ames Hall 2012 NC GOLD 55,713
6 2013 H ST NW 2013 NC GOLD 33,884
7 Law Clinic 2014 NC GOLD 27,651
8 Museum Conservation Center 2014 NC SILVER 55,050
9 LLC and G St Garage 2014 NC SILVER 37,658
10 School of Public Health 2014 NC PLATINUM 130,807
11 GW Museum 2014 NC GOLD 50,394
12 Science and Engineering Hall 2015 NC GOLD 431,717
13 District House Residence Hall 2017 NC GOLD 319,460
14 Ross Hall 2014 CI GOLD 34,930
15 Science and Engineering Hall - 7&8 Floors 2016 CI GOLD 77,650
16 1922 F St 2019 CI SILVER 51,261
17 Corcoran Hall 2018 CI GOLD 53,013
18 Thurston Hall 2023 NC Gold 207,820 (Pending)

An inventory of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
---

Optional Fields 

Website URL where information about the institution’s green building design and construction program is available:
Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
Mount Vernon Campus Master Plan indicates that LEED Gold is the target for all new construction and major renovations; Foggy Bottom Campus Master Plan indicates that LEED Silver or the equivalent is the target. In both cases, the DC Bldg Code is the applicable regulation and it requires LEED Silver or Certified.

In 2012, as part of the Sustainable DC Plan to make the District of Columbia a nationwide leader in sustainability, Mayor Vincent C. Gray issued a directive to the District’s Construction Codes Coordinating Board (CCCB) to review, amend and adopt the model 2012 International Codes as published by the International Code Council (ICC). On March 28, 2014, the District officially adopted the 2013 District of Columbia Construction Codes, comprised of the 2012 International Codes and the 2013 DC Construction Codes Supplement. Included in the 2013 DC Construction Codes are the District of Columbia Green Construction Code (GCC) and Energy Conservation Code (ECC), comprised of the 2012 IgCC and IECC, as modified by the 2013 Construction Codes Supplements (12 DCMR K and 12 DCMR I). These codes incorporate many local sustainable, energy- and water efficient building best practices as mandatory requirements, giving the District one of the greenest construction codes in the country. The codes also extend the green building practices legislated by the District of Columbia Green Building Act of 2006 (GBA). DC has since updated the Energy and Green Building Codes. As of 2017, it is now based on the 2015 ICC Model Codes.

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.