Overall Rating Reporter - expired
Overall Score
Liaison Kathleen Hilimire
Submission Date Feb. 21, 2018
Executive Letter Download

STARS v2.1

Fort Lewis College
OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete Reporter
"---" indicates that no data was submitted for this field

Part 1 

Has the institution conducted a GHG emissions inventory that includes all Scope 1 and 2 emissions? :
Yes

Does the institution’s GHG emissions inventory include all, some or none of its Scope 3 GHG emissions from the following categories?:
All, Some, or None
Business travel Some
Commuting Some
Purchased goods and services None
Capital goods None
Waste generated in operations All
Fuel- and energy-related activities not included in Scope 1 or Scope 2 All
Other categories Some

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory, including how the institution accounted for each category of Scope 3 emissions reported above:
SIMAP. We selected this tool because it was user-friendly and SIMAP was working closely with AASHE on climate action planning based on this tool.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the internal and/or external verification process:
The GHG inventory was conducted by Sightlines, an consulting firm and independent, external third party.

Documentation to support the internal and/or external verification process:
---

Does the institution wish to pursue Part 2 and Part 3 of this credit? (reductions in Scope 1 and Scope 2 GHG emissions):
Yes

Part 2 

Gross Scope 1 and Scope 2 GHG emissions:
Performance Year Baseline Year
Gross Scope 1 GHG emissions from stationary combustion 3,209.90 Metric tons of CO2 equivalent 4,303.50 Metric tons of CO2 equivalent
Gross Scope 1 GHG emissions from other sources 239.50 Metric tons of CO2 equivalent 218.80 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from purchased electricity 8,289.34 Metric tons of CO2 equivalent 11,002.60 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Total 11,738.74 Metric tons of CO2 equivalent 15,524.90 Metric tons of CO2 equivalent

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year July 1, 2016 June 30, 2017
Baseline Year July 1, 2010 June 30, 2011

A brief description of when and why the GHG emissions baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):
---

Figures needed to determine total carbon offsets:
Performance Year Baseline Year
Third-party verified carbon offsets purchased (exclude purchased RECs/GOs) 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 1.18 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon offsets included above for which the emissions reductions have been sold or transferred by the institution 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Net carbon offsets 1.18 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

If total performance year carbon offsets are greater than zero, provide:

A brief description of the offsets in each category reported above, including vendor, project source, verification program and contract timeframes (as applicable):
The Rocket Composter was an initiative led by the students of the Fort Lewis College Environmental Center. This composter saves thousands of pounds of discarded food waste from ending up in landfills. Offsets are calculated by taking the total gallons of compost and converting to tons. MTCDEs are calculated using SIMAP.

The reporting fields in the table below are reserved for institutions that have NOT already accounted for renewable energy purchases (including RECs and GOs) in their Scope 2 GHG emissions calculations. Other institutions - including all SIMAP users - should report zero ('0') to avoid double-counting. 

Emissions reductions attributable to Renewable Energy Certificate (REC) or Guarantee of Origin (GO) purchases:
Performance Year Baseline Year
Emissions reductions attributable to REC/GO purchases 4,392 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the purchased RECs/GOs including vendor, project source and verification program:
Fort Lewis College purchases RECs from two sources: 1) La Plata Electric Association Tri-State Voluntary Renewable Resource Program, certified by WREGIS and M-Rets and 2) Renewable Choice Energy American Wind, certified by Green-e.

Adjusted net Scope 1 and 2 GHG emissions:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions 7,345.56 Metric tons of CO2 equivalent 15,524.90 Metric tons of CO2 equivalent

Figures needed to determine “Weighted Campus Users”:
Performance Year Baseline Year
Number of students resident on-site 1,435 1,314
Number of employees resident on-site 0 1
Number of other individuals resident on-site and/or staffed hospital beds 0 0
Total full-time equivalent student enrollment 3,043 3,575
Full-time equivalent of employees (staff + faculty) 523 484
Full-time equivalent of students enrolled exclusively in distance education 0 0
Weighted campus users 3,033.25 3,373

Adjusted net Scope 1 and 2 GHG emissions per weighted campus user:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user 2.42 Metric tons of CO2 equivalent 4.60 Metric tons of CO2 equivalent

Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
47.39

Part 3

Gross floor area of building space, performance year:
1,237,786 Gross square feet

Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 72,372 Square feet
Healthcare space 0 Square feet
Other energy intensive space 0 Square feet

EUI-adjusted floor area, performance year:
1,382,530 Gross square feet

Adjusted net Scope 1 and 2 GHG emissions per unit of EUI-adjusted floor area, performance year:
0.01 MtCO2e per square foot

Optional Fields 

Scope 3 GHG emissions, performance year:
Emissions
Business travel 490 Metric tons of CO2 equivalent
Commuting 1,488.80 Metric tons of CO2 equivalent
Purchased goods and services 0 Metric tons of CO2 equivalent
Capital goods 0 Metric tons of CO2 equivalent
Fuel- and energy-related activities not included in Scope 1 or Scope 2 0 Metric tons of CO2 equivalent
Waste generated in operations 2,435.20 Metric tons of CO2 equivalent
Other categories 662.50 Metric tons of CO2 equivalent

A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
Efforts to reduce Scope 1 stationary and Scope 2 emissions include performance contracting and building design strategies to reduce energy consumption, and IT purchasing strategies to reduce electric consumption.

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.