5.1 Energy consumption per square meter

Convert site energy figures to megawatt-hours (MWh) using the STARS energy calculator or an equivalent resource.

Performance year for energy use:
2023

Peer group:
Doctoral universities and research institutions

Gross floor area of building space:
372,609.78 Square meters

Electricity
Electricity generated by on-site renewable systems:
2,855 Megawatt-hours

Description of the on-site renewable systems:
  1. Rose Hill Parking Garage Community Solar Project – this 960 kW roof mounted system is the one of the largest Community Solar projects to be hosted by any educational entity in NYC.  System was placed in service in September 2019, and generates nearly 1,000,000 kWh per year.

  2. Campbell Hall Solar Project – this 7.7 kW roof mounted system was installed on the roof of Campbell Hall in 2019.

  3. Walsh Library – the 250 kWh roof mounted solar system was installed in 2012 on the roof of Walsh Library.


On-site renewable electricity exported:
0 Megawatt-hours

Electricity from off-site sources:
4,474 Megawatt-hours

Stationary fuels

Include all liquid, solid, and gaseous fuel products sourced during the performance year for the purpose of producing electricity and/or thermal energy, irrespective of whether they were used or not. Transportation fuels are excluded.

Natural gas:
3,806.41 Megawatt-hours

Propane/LPG:
0 Megawatt-hours

Heating oil:
0 Megawatt-hours

Coal/coke:
0 Megawatt-hours

Bioenergy products:
0 Megawatt-hours

Other stationary fuels:
0 Megawatt-hours

Heating and cooling from off-site sources

Include all district heating and cooling products sourced during the performance year from a utility or municipal facility.

Steam from off-site sources:
2,152.02 Megawatt-hours

Hot water from off-site sources:
0 Megawatt-hours

Chilled water from off-site sources:
0 Megawatt-hours

The Reporting Tool will automatically calculate the following six figures:

Total electricity consumption:
7,329 Megawatt-hours

Total stationary fuel consumption:
3,806.41 Megawatt-hours

Total heating and cooling from off-site sources:
2,152.02 Megawatt-hours

Total annual energy consumption:
13,287.43 Megawatt-hours

Annual energy consumption per unit of floor area:
35.66 Kilowatt-hours per square meter

Points earned for indicator OP 5.1:
3

5.2 Energy consumption per person

Full-time equivalent student enrollment:
16,986

Full-time equivalent of employees:
2,249

The Reporting Tool will automatically calculate the following three figures:

Full-time equivalent students and employees:
19,235

Annual energy consumption per person:
690.79 Kilowatt-hours

Points earned for indicator OP 5.2:
3

5.3 Percentage of energy from renewable sources

Each MWh may only be counted once, i.e., in no more than one of the documentation fields provided. Note that electricity generated by on-site renewable systems is reported above for indicator 5.1. Energy attribute certificates (EACs) include RECs, GOs, and I-RECs.

Contractual instruments for renewable electricity
Energy attribute certificates (EACs) sold or not owned by the institution:
0 Megawatt-hours

Electricity from certified off-site renewable sources:
3,251.97 Megawatt-hours

Description of the certified off-site renewable sources of electricity:

Fordham Staten Island Solar Project – this 2.6 MW ground mounted solar project is the largest solar array dedicated to any educational entity in NYC.  System was formally placed in service in June 2018. The project generates over 3,200,000 kWh per year with Fordham owning and retiring 100% of the associated Renewable Energy Credits. 

 


Electricity from uncertified off-site renewable sources:
0 Megawatt-hours

Description of the uncertified off-site renewable sources of electricity:
---

Certified unbundled EACs:
0 Megawatt-hours

Description of the certified unbundled EACs:
---

Renewable stationary fuels

Convert all units to MWh using the STARS energy calculator or an equivalent resource. Include products sourced during the performance year for the purpose of producing electricity and/or thermal energy, irrespective of whether they were used or not.

Certified bioenergy products:
0 Megawatt-hours

Description of the certified bioenergy products:
---

Uncertified biomethane from organic waste or landfill gas:
0 Megawatt-hours

Description of the uncertified biomethane products:
---

Heating and cooling from off-site renewable sources

For example, district steam or hot water supplied by a municipal geothermal system. Convert all units to MWh using the STARS energy calculator or an equivalent resource.

Heating and cooling from certified off-site renewable sources:
0 Megawatt-hours

Description of the certified off-site renewable sources of heating and cooling:
---

Heating and cooling from uncertified off-site renewable sources:
0 Megawatt-hours

Description of the uncertified off-site renewable sources of heating and cooling:
---

Demand reduction
Description of any cogeneration, solar thermal, geothermal, or similar technologies used by the institution that reduce the demand for non-renewable energy:
---

The Reporting Tool will automatically calculate the following seven figures:

Electricity from on-site renewable systems, rights retained/retired:
2,855 Megawatt-hours

Electricity from renewable sources:
6,106.97 Megawatt-hours

Renewable stationary fuels:
0 Megawatt-hours

Heating and cooling from off-site renewable sources:
0 Megawatt-hours

Annual renewable energy consumption:
6,106.97 Megawatt-hours

Percentage of energy from renewable sources:
45.96

Points earned for indicator OP 5.3:
1.38

5.4 Percentage of electricity from on-site or certified renewable sources

The Reporting Tool will automatically calculate the following three figures:

On-site and/or third party certified renewable power:
6,106.97 Megawatt-hours

Percentage of electricity from on-site and/or third party certified renewable sources:
83.33

Points earned for indicator OP 5.4:
0.83

Optional documentation

Notes about the information provided for this credit:
---

Additional documentation for this credit:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.