Overall Rating Reporter - expired
Overall Score
Liaison Jennifer Lamy
Submission Date March 1, 2018
Executive Letter Download

STARS v2.1

Emerson College
OP-4: Building Design and Construction

Status Score Responsible Party
Complete Reporter Duncan Pollock
AVP Campus Services
Campus Services
"---" indicates that no data was submitted for this field

Total floor area of newly constructed or renovated building space (include projects completed within the previous five years) :
689,450 Square feet

Certified Projects 

Floor area of newly constructed or renovated building space certified Living under the Living Building Challenge:
0 Square feet

Floor area of newly constructed or renovated building space certified at each level under a rating system for design and construction used by an Established Green Building Council (GBC) :
Certified Floor Area
LEED BD+C Platinum or at the highest achievable level under another rating system 0 Square feet
LEED BD+C Gold or at the 2nd highest level under another 4- or 5-tier GBC rating system 382,450 Square feet
Certified at mid-level under a 3- or 5-tier GBC rating system for design and construction (e.g. BREEAM, CASBEE, DGNB, Green Star) 0 Square feet
LEED BD+C Silver or at a step above minimum level under another 4- or 5-tier GBC rating system 0 Square feet
LEED BD+C Certified or certified at minimum level under another GBC rating system 0 Square feet

Floor area of newly constructed or renovated building space certified under a non-GBC rating system for design and construction (e.g. Green Globes NC, Certified Passive House):
0 Square feet

Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
55.47

If reporting certified projects, provide:

A brief description of the green building rating system(s) used and/or a list of certified buildings and ratings:
Included in area: LA Campus building - LEED Gold Colonial building - LEED Gold 2 Boylston Place Building - LEED Gold Not included: Piano Row: 2006 construction, 185,000 square feet, LEED, one of the first two LEED residence halls in Massachusetts

If reporting uncertified projects, provide:

Uncertified Projects 

Floor area of newly constructed or renovated building space that is NOT certified, but that was designed and constructed in accordance with published green building guidelines and policies:
307,000 Square feet

If reporting published green building guidelines or policies, provide the following:

A copy of the green building guidelines or policies :
---

The green building guidelines or policies:
The remainder of the space consists of: Remodeled office space in floors of buildings we lease property from; one of the three buildings included is LEED O+M All of our renovated building spaces, including on leased properties, must utilize energy and water efficient design and operation. We were not able to meet LEED standards for out Paramount Center (residence hall, historic Paramount theatre, and classroom space) because of the historic theatre's energy requirements, which is housed within the Center. However, the Paramount Center was remodeled and constructed with the same resource efficiency standards as all of our LEED buildings. The Center went through renovation and construction and opened for use in 2010. The mechanical, electrical, and plumbing equipment and fixtures were chosen for their energy and resource conservation. The building was designed to meet Massachusetts energy code (https://www.mass.gov/service-details/building-energy-codes).

Do the green building guidelines or policies cover the following?:
Yes or No
Impacts on the surrounding site (e.g. guidelines to reuse previously developed land, protect environmentally sensitive areas, and otherwise minimize site impacts) Yes
Energy consumption (e.g. policies requiring a minimum level of energy efficiency for buildings and their systems) Yes
Building-level energy metering Yes
Use of environmentally preferable materials (e.g. guidelines to minimize the life cycle impacts associated with building materials) Yes
Indoor environmental quality (i.e. guidelines to protect the health and comfort of building occupants) Yes
Water consumption (e.g. requiring minimum standards of efficiency for indoor and outdoor water use) Yes
Building-level water metering Yes

A brief description of the green building guidelines or policies and/or a list or sample of buildings covered:
All new building construction must be LEED B+D certified. All remodels and renovations, both in Emerson owned and leased spaces, must follow energy and water efficiency guidelines, requiring us to create resource saving infrastructure and resource saving technologies.

None
A brief description of how the institution ensures compliance with green building design and construction guidelines and policies:
We have a construction department that works with architects and construction companies with oversight from Emerson senior leadership, USGBC and the City of Boston. All building renovation and construction plans must go through detailed monitoring to ensure compliance with the college's and city's green building policies.

Optional Fields 

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.