Overall Rating | Silver - expired |
---|---|
Overall Score | 54.08 |
Liaison | Jamey Pavey |
Submission Date | Feb. 26, 2016 |
Executive Letter | Download |
Earlham College
OP-1: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
3.04 / 10.00 |
Lisa
Butch Assistant Director of Sustainability Center for Integrated Learning |
"---"
indicates that no data was submitted for this field
None
Does the institution's GHG emissions inventory include all Scope 1 and Scope 2 GHG emissions?:
Yes
None
Does the institution's GHG emissions inventory include all Scope 3 GHG emissions from any of the following categories?:
Yes or No | |
Business travel | No |
Commuting | No |
Purchased goods and services | No |
Capital goods | No |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | Yes |
Waste generated in operations | Yes |
None
Does the institution's GHG emissions inventory include Scope 3 emissions from other categories?:
Yes
None
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
From 2009 to 2013, we used the Clean Air-Cool Planet’s Campus Carbon Calculator.
From 2013, we started using the Carbon Management and Analysis Platform (CarbonMAP). For 2015-16 we used CarbonMAP online at campuscarbon.com
None
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No
None
A brief description of the internal and/or external verification process:
---
None
Scope 1 and Scope 2 GHG emissions::
Performance Year | Baseline Year | |
Scope 1 GHG emissions from stationary combustion | 4,571.78 Metric tons of CO2 equivalent | 4,245.10 Metric tons of CO2 equivalent |
Scope 1 GHG emissions from other sources | 35.84 Metric tons of CO2 equivalent | 90.47 Metric tons of CO2 equivalent |
Scope 2 GHG emissions from purchased electricity | 9,563.61 Metric tons of CO2 equivalent | 8,691.88 Metric tons of CO2 equivalent |
Scope 2 GHG emissions from other sources | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
None
Figures needed to determine total carbon offsets::
Performance Year | Baseline Year | |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon sequestration due to land that the institution manages specifically for sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
None
A brief description of the institution-catalyzed carbon offsets program:
NA
None
A brief description of the carbon sequestration program and reporting protocol used:
Earlham College owns many young and old woods, which contributes to the sequestration of carbon dioxide emitted by the campus. We estimated the carbon dioxide sequestration by firstly obtaining the total acres from an online software, Wayne County Data Sever. Then we adapted a method of estimating the carbon dioxide sequestration from a scientific paper.
None
A brief description of the composting and carbon storage program:
NA
None
A brief description of the purchased carbon offsets, including third party verifier(s) and contract timeframes:
N/A
None
Figures needed to determine “Weighted Campus Users”::
Performance Year | Baseline Year | |
Number of residential students | 845 | 1,258 |
Number of residential employees | 4 | 0 |
Number of in-patient hospital beds | 0 | 0 |
Full-time equivalent enrollment | 982 | 1,258 |
Full-time equivalent of employees | 371 | 330 |
Full-time equivalent of distance education students | 0 | 0 |
None
Start and end dates of the performance year and baseline year (or three-year periods):
Start Date | End Date | |
Performance Year | Jan. 1, 2015 | Dec. 31, 2015 |
Baseline Year | July 1, 2007 | June 30, 2008 |
None
A brief description of when and why the GHG emissions baseline was adopted:
The baseline year we selected is the first year that we had all the data entries.
None
Gross floor area of building space, performance year:
1,114,807
Square feet
None
Floor area of energy intensive building space, performance year:
Floor Area | |
Laboratory space | 51,380 Square feet |
Healthcare space | 2,000 Square feet |
Other energy intensive space | 58,000 Square feet |
None
Scope 3 GHG emissions, performance year::
Emissions | |
Business travel | 0 Metric tons of CO2 equivalent |
Commuting | 0 Metric tons of CO2 equivalent |
Purchased goods and services | 0 Metric tons of CO2 equivalent |
Capital goods | 0 Metric tons of CO2 equivalent |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | 0 Metric tons of CO2 equivalent |
Waste generated in operations | 75.65 Metric tons of CO2 equivalent |
Other categories (please specify below) | 533.87 Metric tons of CO2 equivalent |
None
A brief description of the sources included in Scope 3 GHG emissions from "other categories":
Study abroad air travel
None
A copy of the most recent GHG emissions inventory:
None
The website URL where the GHG emissions inventory is posted:
---
None
A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
---
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.