Overall Rating | Gold |
---|---|
Overall Score | 72.00 |
Liaison | Jessica Krejcik |
Submission Date | Dec. 22, 2021 |
Concordia University
OP-6: Clean and Renewable Energy
Status | Score | Responsible Party |
---|---|---|
0.00 / 4.00 |
Daniel
Gauthier Building Performance Coordinator Facilities Management |
"---"
indicates that no data was submitted for this field
Total energy consumption, performance year:
546,035.61
MMBtu
Clean and renewable electricity (report kilowatt-hours):
kWh | MMBtu | |
Imported electricity from certified/verified clean and renewable sources (i.e., bundled green power purchases) | 0 Kilowatt-hours | 0 MMBtu |
Electricity from on-site, clean and renewable sources (rights retained/retired) | 84,000 Kilowatt-hours | 286.61 MMBtu |
A brief description of the certified/verified sources of clean and renewable electricity:
N/A
A brief description of the on-site renewable electricity generating facilities/devices:
The LEED® registered John Molson School of Business building uses a single façade surface to generate both heat and electricity from the sun. This type of solar installation is referred to as a Building Integrated Photovoltaic/Thermal (BIPV/T) application, and it is the first installation of its particular configuration in the world. The combined generation is expected to have an overall efficiency of about 60% (the rate of utilization of incident solar energy).
Clean and renewable thermal energy (report MMBtu):
MMBtu | |
Clean and renewable stationary fuels used on-site to generate thermal energy | 187.50 MMBtu |
Imported steam, hot water, and/or chilled water from certified/verified clean and renewable sources | 0 MMBtu |
A brief description of the clean and renewable stationary fuels:
The LEED® registered John Molson School of Business building uses a single façade surface to generate both heat and electricity from the sun. This type of solar installation is referred to as a Building Integrated Photovoltaic/Thermal (BIPV/T) application, and it is the first installation of its particular configuration in the world. The combined generation is expected to have an overall efficiency of about 60% (the rate of utilization of incident solar energy).
A brief description of the certified/verified sources of clean and renewable thermal energy:
N/A
Unbundled renewable energy products (report kWh):
kWh | MMBtu | |
Purchased RECs, GOs, I-RECs or equivalent unbundled renewable energy products certified by a third party | 0 Kilowatt-hours | 0 MMBtu |
A brief description of the unbundled renewable energy products:
---
Total clean and renewable energy generated or purchased:
474.11
MMBtu
Percentage of total energy consumption from clean and renewable sources:
0.09
Website URL where information about the institution’s support for clean and renewable energy is available:
Electricity use, by source (percentage of total, 0-100):
Percentage of total electricity use (0-100) | |
Biomass | 0 |
Coal | 0 |
Geothermal | 0 |
Hydro | 0 |
Natural gas | 0 |
Nuclear | 0 |
Solar photovoltaic | 0 |
Wind | 0.50 |
Other (please specify and explain below) | 0 |
A brief description of other sources of electricity not specified above:
---
Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100) | |
Biomass | 0 |
Coal | 0 |
Electricity | 0 |
Fuel oil | 0 |
Geothermal | 0 |
Natural gas | 0 |
Other (please specify and explain below) | --- |
A brief description of other sources of building heating not specified above:
---
Additional documentation to support the submission:
---
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.