Overall Rating Silver
Overall Score 48.20
Liaison Lauren Poole
Submission Date Dec. 10, 2021

STARS v2.2

Colorado School of Mines
OP-1: Emissions Inventory and Disclosure

Status Score Responsible Party
Complete 1.88 / 3.00 Lauren Poole
Sustainability Coordinator
EHS
"---" indicates that no data was submitted for this field

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:

This emissions inventory was conducted using the EnergyCAP software, which tracks emissions based on utility bills, utility loads, and other financially traceable consumption. This emissions inventory was conducted by McKinstry, a third-party energy analysis company, and vetted by Mines Facilities Management.


Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the GHG inventory verification process:

The GHG inventory verification process was done through the corroboration of separate calculations of Scope 1 and 2 emissions by McKinstry, Sustainability Interns with the Sustainability Office, and Facilities Management.


Documentation to support the GHG inventory verification process:
---

Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 10,909 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 0 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
10,909 Metric tons of CO2 equivalent

Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 21,846 Metric tons of CO2 equivalent
Imported thermal energy 0 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
21,846 Metric tons of CO2 equivalent

Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel No ---
Commuting No ---
Purchased goods and services No ---
Capital goods No ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 No ---
Waste generated in operations No ---
Other sources No ---

Total Scope 3 GHG emissions, performance year:
0 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:
---

Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
No

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) 0 Tons
Sulfur oxides (SOx) 0 Tons
Carbon monoxide (CO) 0 Tons
Particulate matter (PM) 0 Tons
Ozone (O3) 0 Tons
Lead (Pb) 0 Tons
Hazardous air pollutants (HAPs) 0 Tons
Ozone-depleting compounds (ODCs) 0 Tons
Other standard categories of air emissions identified in permits and/or regulations 0 Tons

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources ---
Area sources ---
Mobile sources ---
Commuting ---
Off-site electricity production ---

A brief description of the methodology(ies) the institution used to complete its air emissions inventory:

The institution plans on using EnergyCAP in the near future to develop an air emissions inventory.


Gross Scope 2 GHG emissions from purchased electricity (location-based):
21,846 Metric tons of CO2 equivalent

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
0 Metric tons of CO2 equivalent

Website URL where information about the institution’s emissions inventories is available:
Additional documentation to support the submission:
Data source(s) and notes about the submission:

In 2017, the university renovated an old heating plant on campus and started producing its own steam instead of importing steam from Coors in Golden, which used primarily coal to produce steam. The baseline year will show some imported steam because the new steam plant on campus became operational in about April 2017. After that, we did not import steam because we produced our own steam with 100% natural gas.


In 2017, the university renovated an old heating plant on campus and started producing its own steam instead of importing steam from Coors in Golden, which used primarily coal to produce steam. The baseline year will show some imported steam because the new steam plant on campus became operational in about April 2017. After that, we did not import steam because we produced our own steam with 100% natural gas.

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.