California State University, Channel Islands
OP-5: Indoor Air Quality

Status Score Responsible Party
Complete 1.00 / 1.00 Jose Antonio Chanes
AD of Infrastructure and Energy
Facilities Services
"---" indicates that no data was submitted for this field

None
Floor area of building space covered by an indoor air quality (IAQ) management program that meets the criteria for this credit:
733,002 Square feet

None
Gross floor area of building space:
733,002 Square feet

None
A brief description of the institution’s indoor air quality program(s) (including information about regular auditing or monitoring, mechanisms for occupants to register complaints, and action plans):
California State University Channel Islands (CI) uses Publication EPA 402-K-98-001 as a basis for CI’s Indoor Air Quality Action Plan. With Demand Control Ventilation, the buildings control system, CI can ensure a learning environment that requires the CO2 levels for the classrooms and offices to be maintained at less than 1000 PPM. When CI’s CO2 levels rise from the set 800 PPM, the controls automatically open the outside air dampers to introduce more fresh air and remove the CO2 content. To keep the conditions comfortable and ensure a proper flushing of contaminates, CI has adopted an ASHRAE (The American Society of Heating, Refrigerating and Air-Conditioning Engineers) standards of a minimum of four air changes per hour. In addition, CI performs annual checks of CO2 sensors that provide the primary input for controlling the concentration of CO2. Another key element in ensuring the proper CO2 levels and particulate filtration, CI has a preventative maintenance (PM) program in place to ensure correct equipment and filtering operation. The dust efficiency ratings for the HVAC air filters are high efficiency filters (85%). They are changed during the normal scheduled PM process or if the system detects a high differential pressure across the filter. To ensure the reliability of the filtration all filter bank seals are inspected during PM’s. CI, as well, takes complaints very seriously. Complaints are logged into our work order system, CMMS, for proper tracking and resolution. Actions would include meeting with the complainant, identifying possible causes and steps that may include verifications of air flows, a recheck on control sensors, and physical checks on all equipment. Adjustments or actions are made as needed at that time and verified for mitigation of the issue.

None
The website URL where information about the institution’s indoor air quality program(s) is available:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.