OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 6.32 / 10.00 Monika Kamboures
Sustainability Coordinator
Office of Planning, Sustainability & Transportation
"---" indicates that no data was submitted for this field

Part 1 

Has the institution conducted a GHG emissions inventory that includes all Scope 1 and 2 emissions? :
Yes

Does the institution’s GHG emissions inventory include all, some or none of its Scope 3 GHG emissions from the following categories?:
All, Some, or None
Business travel All
Commuting All
Purchased goods and services None
Capital goods None
Waste generated in operations Some
Fuel- and energy-related activities not included in Scope 1 or Scope 2 All
Other categories None

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory, including how the institution accounted for each category of Scope 3 emissions reported above:
We have continued to use the UNH Campus Carbon Calculator. Information was requested from departments throughout campus to gather data for the calculator. The commuting information was compiled from faculty, staff, and student surveys. Our accounting department and international center we able to provide directly financed travel data while the international center supplied us with study abroad data. While we do have data on landfill methane, composting, and RECs, they were not included in our most recent inventory calculator.

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No

A brief description of the internal and/or external verification process:
---

Documentation to support the internal and/or external verification process:
---

Does the institution wish to pursue Part 2 and Part 3 of this credit? (reductions in Scope 1 and Scope 2 GHG emissions):
Yes

Part 2 

Gross Scope 1 and Scope 2 GHG emissions:
Performance Year Baseline Year
Gross Scope 1 GHG emissions from stationary combustion 4,770 Metric tons of CO2 equivalent 10,962 Metric tons of CO2 equivalent
Gross Scope 1 GHG emissions from other sources 1,419 Metric tons of CO2 equivalent 2,050 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from purchased electricity 16,741 Metric tons of CO2 equivalent 18,516 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Total 22,930 Metric tons of CO2 equivalent 31,528 Metric tons of CO2 equivalent

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year July 1, 2017 June 30, 2018
Baseline Year July 1, 2005 June 30, 2006

A brief description of when and why the GHG emissions baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):
---

Figures needed to determine total carbon offsets:
Performance Year Baseline Year
Third-party verified carbon offsets purchased (exclude purchased RECs/GOs) 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon offsets included above for which the emissions reductions have been sold or transferred by the institution 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Net carbon offsets 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

If total performance year carbon offsets are greater than zero, provide:

A brief description of the offsets in each category reported above, including vendor, project source, verification program and contract timeframes (as applicable):
---

The reporting fields in the table below are reserved for institutions that have NOT already accounted for renewable energy purchases (including RECs and GOs) in their Scope 2 GHG emissions calculations. Other institutions - including all SIMAP users - should report zero ('0') to avoid double-counting. 

Emissions reductions attributable to Renewable Energy Certificate (REC) or Guarantee of Origin (GO) purchases:
Performance Year Baseline Year
Emissions reductions attributable to REC/GO purchases 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the purchased RECs/GOs including vendor, project source and verification program:
---

Adjusted net Scope 1 and 2 GHG emissions:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions 22,930 Metric tons of CO2 equivalent 31,528 Metric tons of CO2 equivalent

Figures needed to determine “Weighted Campus Users”:
Performance Year Baseline Year
Number of students resident on-site 3,588 2,500
Number of employees resident on-site 3 3
Number of other individuals resident on-site and/or staffed hospital beds 3 0
Total full-time equivalent student enrollment 22,609 16,295
Full-time equivalent of employees (staff + faculty) 2,107 2,130
Full-time equivalent of students enrolled exclusively in distance education 0 0
Weighted campus users 19,437.75 14,444.50

Adjusted net Scope 1 and 2 GHG emissions per weighted campus user:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user 1.18 Metric tons of CO2 equivalent 2.18 Metric tons of CO2 equivalent

Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
45.95

Part 3

Gross floor area of building space, performance year:
5,055,814 Gross square feet

Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 128,951 Square feet
Healthcare space 11,291 Square feet
Other energy intensive space 44,565 Square feet

EUI-adjusted floor area, performance year:
5,380,863 Gross square feet

Adjusted net Scope 1 and 2 GHG emissions per unit of EUI-adjusted floor area, performance year:
0.00 MtCO2e per square foot

Optional Fields 

Scope 3 GHG emissions, performance year:
Emissions
Business travel 3,128 Metric tons of CO2 equivalent
Commuting 18,746 Metric tons of CO2 equivalent
Purchased goods and services ---
Capital goods ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 ---
Waste generated in operations ---
Other categories ---

A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
We have been signatories of Second Nature's Carbon Commitment since 2005 and have continued work on the Climate Action Plan adopted but the campus. More information can be found on the campus link.

The website URL where information about the programs or initiatives is available:
Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
It should be noted that all efforts were taken to ensure that data was accurate.

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.