Bowling Green State University
OP-3: Building Design and Construction
Status | Score | Responsible Party |
---|---|---|
![]() |
Reporter |
Total floor area of newly constructed or renovated building space:
Floor area of eligible building space designed and built in accordance with published green building codes, policies, and/or rating systems:
Floor area | |
Certified at the highest achievable level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Platinum or Certified Living Building) | 0 Square feet |
Certified at the 2nd highest level under a 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Gold) | 0 Square feet |
Certified at mid-level under a 3- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., BREEAM Very Good) | 0 Square feet |
Certified at a step above minimum level under ar 4- or 5-tier, multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Silver) | 89,738 Square feet |
Certified at minimum level under a multi-attribute GBC rating system for design and construction (e.g., LEED BD+C Certified) | 0 Square feet |
Certified/verified at any level under a multi-attribute, non-GBC rating system for design and construction, a green building code, or a single-attribute rating system for design and construction | 0 Square feet |
Designed and built in accordance with a multi-attribute green building code, policy, guideline, or rating system, but not certified/verified | 0 Square feet |
Designed and built in accordance with a single-attribute green building code, policy, guideline, or rating system, but not certified/verified | 24,229 Square feet |
Total | 113,967 Square feet |
Percentage of newly constructed or renovated building space certified under a green building rating system for design and construction:
A list of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
Maurer Center (Built 2020-2021)

- CreditIntegrative process1 / 1




- PrereqFundamental commissioning and verification0 / 0
- PrereqMinimum energy performance0 / 0
- PrereqBuilding-level energy metering0 / 0
- PrereqFundamental refrigerant management0 / 0
- PrereqMinimum Energy Performance (2024 Update)0 / 0
- CreditEnhanced commissioning6 / 6
- CreditAdvanced energy metering1 / 1
- CreditDemand response2 / 2
- CreditRenewable energy production0 / 3
- CreditEnhanced refrigerant management0 / 1
- CreditGreen power and carbon offsets0 / 2
- CreditOptimize Energy Performance (2024 Update)0 / 20
- CreditOptimize energy performance4 / 18

- PrereqStorage and collection of recyclables0 / 0
- PrereqConstruction and demolition waste management planning0 / 0
- CreditBuilding life-cycle impact reduction0 / 5
- CreditBuilding product disclosure and optimization - environmental product d...1 / 2
- CreditBuilding product disclosure and optimization - sourcing of raw materia...1 / 2
- CreditBuilding product disclosure and optimization - material ingredients1 / 2
- CreditConstruction and demolition waste management2 / 2

- PrereqMinimum indoor air quality performance0 / 0
- PrereqEnvironmental tobacco smoke control0 / 0
- CreditEnhanced indoor air quality strategies2 / 2
- CreditLow-emitting materials3 / 3
- CreditConstruction indoor air quality management plan1 / 1
- CreditIndoor air quality assessment2 / 2
- CreditThermal comfort1 / 1
- CreditInterior lighting1 / 2
- CreditDaylight0 / 3
- CreditQuality views1 / 1
- CreditAcoustic performance0 / 1

- CreditInnovation4 / 5
- CreditLEED Accredited Professional1 / 1
Kokosing Hall Major Renovation Completed 2022-2023 added 24,229 square feet of space to the LEED Silver Certified Park Avenue Building, a warehouse that was renovated in 2018. Additional space was added for computer labs and architecture design, and the former warehouse was retrofitted for offices and architecture workspace as well. This square footage addition was designed and built in accordance with a single-attribute green building code, policy, guideline, or rating system, but not certified/verified.
An inventory of new construction and major renovation projects that indicates the green building code, policy/guideline, or rating system that applies to each building:
Optional Fields
Additional documentation to support the submission:
Data source(s) and notes about the submission:
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.