Overall Rating | Gold |
---|---|
Overall Score | 66.30 |
Liaison | Stephen Ellis |
Submission Date | May 31, 2024 |
Boston University
OP-2: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
6.17 / 8.00 |
Stephen
Ellis Director, Data Analytics BU Sustainability |
Scope 1 and Scope 2 GHG emissions
Gross GHG emissions
Performance year | Baseline year | |
Gross Scope 1 GHG emissions from stationary combustion | 46,500 Metric tons of CO2 equivalent | 58,825 Metric tons of CO2 equivalent |
Gross Scope 1 GHG emissions from other sources | 1,900 Metric tons of CO2 equivalent | 1,802 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported electricity | 0 Metric tons of CO2 equivalent | 91,795 Metric tons of CO2 equivalent |
Gross Scope 2 GHG emissions from imported thermal energy | 9,200 Metric tons of CO2 equivalent | 13,013 Metric tons of CO2 equivalent |
Total | 57,600 Metric tons of CO2 equivalent | 165,435 Metric tons of CO2 equivalent |
Carbon sinks
Performance year | Baseline year | |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from non-additional sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon sold or transferred | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Net carbon sinks | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
If total performance year carbon sinks are greater than zero, provide:
Adjusted net GHG emissions
Performance year | Baseline year | |
Adjusted net GHG emissions | 57,600 Metric tons of CO2 equivalent | 165,435 Metric tons of CO2 equivalent |
Performance and baseline periods
Performance year | Baseline year | |
Start date | July 1, 2022 | July 1, 2005 |
End date | June 30, 2023 | June 30, 2006 |
A brief description of when and why the GHG emissions baseline was adopted:
Beginning in 2019, in an effort to capture a more complete picture of our emissions, we included fleet, fugitive, and shuttle emissions under Scope 1 - other sources. These figures had not been included in the past because of missing or incorrect data dating back to FY2006. Historically, the boundary for the University's STARS reports has been limited to the Charles River and Medical Campuses. For the first time, in 2019, we captured emissions data from facilities off-campus within New England. In addition, on June 1, 2018, Wheelock College merged with BU, becoming the Fenway Campus; this campus is included in our institutional boundary. For consistency, Boston University uses a Fiscal Year 2006 baseline for its sustainability metrics.
Part 1. Reduction in GHG emissions per person
Weighted campus users
Performance year | Baseline year | |
Number of students resident on-site | 11,441 | 11,185 |
Number of employees resident on-site | 191 | 181 |
Number of other individuals resident on-site | 0 | 0 |
Total full-time equivalent student enrollment | 29,964 | 24,623 |
Full-time equivalent of employees | 9,780 | 8,439 |
Full-time equivalent of students enrolled exclusively in distance education | 1,505 | 1,605 |
Weighted Campus Users | 31,587.25 | 26,434.25 |
Metrics used in scoring for Part 1
Performance year | Baseline year | |
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user | 1.82 Metric tons of CO2 equivalent | 6.26 Metric tons of CO2 equivalent |
Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
Part 2. GHG emissions per unit of floor area
Performance year floor area
Floor area of energy intensive building space, performance year:
Floor area | |
Laboratory space | 657,844.05 Square feet |
Healthcare space | 79,475.10 Square feet |
Other energy intensive space | 239,235.20 Square feet |
EUI-adjusted floor area, performance year:
Metric used in scoring for Part 2
A brief description of the institution’s GHG emissions reduction initiatives:
BU's initiatives to reduce greenhouse gas emissions can be found at the following website and in the following document:
- BU Sustainability's Climate Action website:
https://www.bu.edu/sustainability/vision-progress/climate-action-plan-2/#section-0-article-0 - BU's Climate Action Plan: https://www.bu.edu/sustainability/files/2021/05/BUClimateActionPlan_Report_FINAL.pdf
Website URL where information about the institution's GHG emissions is available:
Additional documentation to support the submission:
Data source(s) and notes about the submission:
As part of our Climate Action Plan, BU matches 100% of our scope 2 electricity needs by retiring Renewable Energy Certificates (RECs) from the BU Wind Farm. This project came online in December 2020 in the middle of FY2021 and reduced our carbon emissions by 58.3%. It has continued since and matched 100% electricity for FY2023. Hence the drop in electricity emissions from previous years is from BU Wind Farm matching electricity by wind power.
This represents FY2023 BU Metrics.
Additional links highlighting BU's Climate Action Plan: Net Zero Direct Emissions:
- https://www.bu.edu/sustainability/projects/net-zero-direct-emissions/ Act on Indirect Emissions:
- https://www.bu.edu/sustainability/projects/act-on-indirect-emissions/
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.