Overall Rating Gold - expired
Overall Score 66.60
Liaison Mary Lucus
Submission Date Feb. 26, 2019
Executive Letter Download

STARS v2.1

Belmont University
OP-1: Greenhouse Gas Emissions

Status Score Responsible Party
Complete 4.05 / 10.00 Mary Lucus
Director, IR
Provost
"---" indicates that no data was submitted for this field

Has the institution conducted a GHG emissions inventory that includes all Scope 1 and 2 emissions? :
Yes

Does the institution’s GHG emissions inventory include all, some or none of its Scope 3 GHG emissions from the following categories?:
All, Some, or None
Business travel None
Commuting None
Purchased goods and services None
Capital goods None
Waste generated in operations None
Fuel- and energy-related activities not included in Scope 1 or Scope 2 None
Other categories None

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory, including how the institution accounted for each category of Scope 3 emissions reported above:

Scope 1 emissions calculated through spreadsheets using factors provided by EPA for diesel and natural gas emissions.
Used tool from Greenhouse Gas Protocol to calculate scope 2 emission based on actual consumption records. This tool is tailored to specific regions and allows us to calculate emissions based on TVA's mix of generating capacity.


Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes

A brief description of the internal and/or external verification process:

Scope 1 calculation procedures and results are submitted to Metro Nashville Health Department for verification review and renewal of Federal EPA Air Permit.
I C Thomasson Associates, Inc. (ICT) a consulting engineering firm has been retained to review and comment on our Scope 1 and Scope 2 emissions calculation procedures and results.


Documentation to support the internal and/or external verification process:
Does the institution wish to pursue Part 2 and Part 3 of this credit? (reductions in Scope 1 and Scope 2 GHG emissions):
Yes

Gross Scope 1 and Scope 2 GHG emissions:
Performance Year Baseline Year
Gross Scope 1 GHG emissions from stationary combustion 5,954 Metric tons of CO2 equivalent 6,832 Metric tons of CO2 equivalent
Gross Scope 1 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from purchased electricity 28,602.80 Metric tons of CO2 equivalent 22,767.70 Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from other sources 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Total 34,556.80 Metric tons of CO2 equivalent 29,599.70 Metric tons of CO2 equivalent

Start and end dates of the performance year and baseline year (or three-year periods):
Start Date End Date
Performance Year June 1, 2017 May 31, 2018
Baseline Year June 1, 2013 May 31, 2014

A brief description of when and why the GHG emissions baseline was adopted (e.g. in sustainability plans and policies or in the context of other reporting obligations):

Baseline was adopted for this report.
Stationary combustion emissions are seeing a positive reduction due to the university replacing older fuel burning equipment with higher efficiency boilers and condensing boilers.
Purchased electricity emissions are the result of adding additional buildings across campus.


Figures needed to determine total carbon offsets:
Performance Year Baseline Year
Third-party verified carbon offsets purchased (exclude purchased RECs/GOs) 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Institution-catalyzed carbon offsets generated 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon sequestration due to land that the institution manages specifically for sequestration 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon storage from on-site composting 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Carbon offsets included above for which the emissions reductions have been sold or transferred by the institution 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent
Net carbon offsets 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the offsets in each category reported above, including vendor, project source, verification program and contract timeframes (as applicable):

No carbon offsets pursued at this time.


Emissions reductions attributable to Renewable Energy Certificate (REC) or Guarantee of Origin (GO) purchases:
Performance Year Baseline Year
Emissions reductions attributable to REC/GO purchases 0 Metric tons of CO2 equivalent 0 Metric tons of CO2 equivalent

A brief description of the purchased RECs/GOs including vendor, project source and verification program:

No REC's pursued at this time.


Adjusted net Scope 1 and 2 GHG emissions:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions 34,556.80 Metric tons of CO2 equivalent 29,599.70 Metric tons of CO2 equivalent

Figures needed to determine “Weighted Campus Users”:
Performance Year Baseline Year
Number of students resident on-site 3,565 2,804
Number of employees resident on-site 0 0
Number of other individuals resident on-site and/or staffed hospital beds 0 0
Total full-time equivalent student enrollment 7,987 6,558
Full-time equivalent of employees (staff + faculty) 1,085 1,023
Full-time equivalent of students enrolled exclusively in distance education 17 0
Weighted campus users 7,682.50 6,386.75

Adjusted net Scope 1 and 2 GHG emissions per weighted campus user:
Performance Year Baseline Year
Adjusted net Scope 1 and 2 GHG emissions per weighted campus user 4.50 Metric tons of CO2 equivalent 4.63 Metric tons of CO2 equivalent

Percentage reduction in adjusted net Scope 1 and Scope 2 GHG emissions per weighted campus user from baseline:
2.94

Gross floor area of building space, performance year:
4,262,100 Gross square feet

Floor area of energy intensive building space, performance year:
Floor Area
Laboratory space 42,142 Square feet
Healthcare space 1,930 Square feet
Other energy intensive space 48,980 Square feet

EUI-adjusted floor area, performance year:
4,399,224 Gross square feet

Adjusted net Scope 1 and 2 GHG emissions per unit of EUI-adjusted floor area, performance year:
0.01 MtCO2e per square foot

Scope 3 GHG emissions, performance year:
Emissions
Business travel ---
Commuting ---
Purchased goods and services ---
Capital goods ---
Fuel- and energy-related activities not included in Scope 1 or Scope 2 ---
Waste generated in operations ---
Other categories ---

A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
---

The website URL where information about the programs or initiatives is available:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.