Overall Rating | Gold - expired |
---|---|
Overall Score | 69.35 |
Liaison | Mary Lucus |
Submission Date | March 14, 2016 |
Executive Letter | Download |
Belmont University
OP-1: Greenhouse Gas Emissions
Status | Score | Responsible Party |
---|---|---|
3.53 / 10.00 |
Mary
Lucus Director, IR Provost |
"---"
indicates that no data was submitted for this field
None
Does the institution's GHG emissions inventory include all Scope 1 and Scope 2 GHG emissions?:
Yes
None
Does the institution's GHG emissions inventory include all Scope 3 GHG emissions from any of the following categories?:
Yes or No | |
Business travel | No |
Commuting | No |
Purchased goods and services | No |
Capital goods | No |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | No |
Waste generated in operations | No |
None
Does the institution's GHG emissions inventory include Scope 3 emissions from other categories?:
No
None
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
Used tool from Greenhouse Gas Protocol to calculate based on actual records. Baseline established by averaging last three performance years
None
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No
None
A brief description of the internal and/or external verification process:
N/A
None
Scope 1 and Scope 2 GHG emissions::
Performance Year | Baseline Year | |
Scope 1 GHG emissions from stationary combustion | 25.18 Metric tons of CO2 equivalent | 17.73 Metric tons of CO2 equivalent |
Scope 1 GHG emissions from other sources | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Scope 2 GHG emissions from purchased electricity | 25,147.51 Metric tons of CO2 equivalent | 22,767.74 Metric tons of CO2 equivalent |
Scope 2 GHG emissions from other sources | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
None
Figures needed to determine total carbon offsets::
Performance Year | Baseline Year | |
Institution-catalyzed carbon offsets generated | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon sequestration due to land that the institution manages specifically for sequestration | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Carbon storage from on-site composting | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
Third-party verified carbon offsets purchased | 0 Metric tons of CO2 equivalent | 0 Metric tons of CO2 equivalent |
None
A brief description of the institution-catalyzed carbon offsets program:
There is none
None
A brief description of the carbon sequestration program and reporting protocol used:
There is none
None
A brief description of the composting and carbon storage program:
Composting of yard waste is done throughout the year, but GHG emission reductions are not measured.
None
A brief description of the purchased carbon offsets, including third party verifier(s) and contract timeframes:
None
None
Figures needed to determine “Weighted Campus Users”::
Performance Year | Baseline Year | |
Number of residential students | 3,115 | 2,804 |
Number of residential employees | 0 | 0 |
Number of in-patient hospital beds | 0 | 0 |
Full-time equivalent enrollment | 6,890 | 6,558 |
Full-time equivalent of employees | 1,067 | 1,023 |
Full-time equivalent of distance education students | 0 | 0 |
None
Start and end dates of the performance year and baseline year (or three-year periods):
Start Date | End Date | |
Performance Year | June 1, 2014 | May 31, 2015 |
Baseline Year | June 1, 2011 | May 31, 2014 |
None
A brief description of when and why the GHG emissions baseline was adopted:
Baseline was adopted for this report.
None
Gross floor area of building space, performance year:
3,986,342
Square feet
None
Floor area of energy intensive building space, performance year:
Floor Area | |
Laboratory space | 42,142 Square feet |
Healthcare space | 1,930 Square feet |
Other energy intensive space | 48,980 Square feet |
None
Scope 3 GHG emissions, performance year::
Emissions | |
Business travel | --- |
Commuting | --- |
Purchased goods and services | --- |
Capital goods | --- |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | --- |
Waste generated in operations | --- |
Other categories (please specify below) | --- |
None
A brief description of the sources included in Scope 3 GHG emissions from "other categories":
---
None
A copy of the most recent GHG emissions inventory:
None
The website URL where the GHG emissions inventory is posted:
---
None
A brief description of the institution’s GHG emissions reduction initiatives, including efforts made during the previous three years:
Emission reductions have been achieved by the retrofitting of buildings with higher efficiency boilers and chillers, LED lighting, geothermal heating and cooling and chilled beam technology.
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.