Overall Rating Gold - expired
Overall Score 66.69
Liaison Laurie Husted
Submission Date June 8, 2020

STARS v2.2

Bard College
OP-6: Clean and Renewable Energy

Status Score Responsible Party
Complete 0.25 / 4.00 Dan Smith
Energy Efficiency Coordinator
Office of Sustainability
"---" indicates that no data was submitted for this field

Total energy consumption (electric and non-electric)

Total energy consumption, performance year:
122,657.37 MMBtu

Clean and renewable energy sources

Clean and renewable electricity

Clean and renewable electricity (report kilowatt-hours):
kWh MMBtu
Imported electricity from certified/verified clean and renewable sources (i.e., bundled green power purchases) 0 Kilowatt-hours 0 MMBtu
Electricity from on-site, clean and renewable sources (rights retained/retired) 219,775 Kilowatt-hours 749.87 MMBtu

A brief description of the certified/verified sources of clean and renewable electricity:
---

A brief description of the on-site renewable electricity generating facilities/devices:
280 kW ground-mount photovoltaic array installed in 2013.
9kW roof-top photovoltaic array installed in 2014.

Clean and renewable thermal energy

Clean and renewable thermal energy (report MMBtu):
MMBtu
Clean and renewable stationary fuels used on-site to generate thermal energy 0 MMBtu
Imported steam, hot water, and/or chilled water from certified/verified clean and renewable sources 0 MMBtu

A brief description of the clean and renewable stationary fuels:
---

A brief description of the certified/verified sources of clean and renewable thermal energy:
---

Unbundled renewable energy products

Unbundled renewable energy products (report kWh):
kWh MMBtu
Purchased RECs, GOs, I-RECs or equivalent unbundled renewable energy products certified by a third party 2,000,000 Kilowatt-hours 6,824 MMBtu

A brief description of the unbundled renewable energy products:
2,000,000 kwh offsets that are purchased from Renewable Choice Energy (Green-e® Certified American Wind).

Metrics used in scoring

Total clean and renewable energy generated or purchased:
7,573.87 MMBtu

Percentage of total energy consumption from clean and renewable sources:
6.17

Optional Fields

Website URL where information about the institution’s support for clean and renewable energy is available:

Sierra magazine requests the following information from U.S. institutions that wish to share data with that organization:

Electricity use, by source (percentage of total, 0-100):
Percentage of total electricity use (0-100)
Biomass 2
Coal 0.80
Geothermal 0
Hydro 34.60
Natural gas 25.90
Nuclear 31.30
Solar photovoltaic 0.20
Wind 4.70
Other (please specify and explain below) 0.60

A brief description of other sources of electricity not specified above:
Other = Oil (0.6%)

Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100)
Biomass ---
Coal ---
Electricity ---
Fuel oil ---
Geothermal ---
Natural gas ---
Other (please specify and explain below) ---

A brief description of other sources of building heating not specified above:
---

Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
Grid energy source profile taken from:
https://www.epa.gov/energy/power-profiler#/NYUP

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.