Overall Rating | Silver |
---|---|
Overall Score | 58.58 |
Liaison | Margaret Lo |
Submission Date | July 14, 2022 |
Ball State University
OP-1: Emissions Inventory and Disclosure
Status | Score | Responsible Party |
---|---|---|
2.79 / 3.00 |
Pete
Heuer Director of Operations Facilities |
"---"
indicates that no data was submitted for this field
Part 1. Greenhouse gas emissions inventory
Yes
A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
The EPA provides the template for reporting green house gas emissions. The university enters actual metered data into the template. The EPA then certifies the results. The university Director of Operations enters the data which is checked by the AVP of Facilities Planning nd Management.
EPA GHG web site: https://www.epa.gov/ghgreporting/forms/contact-us-about-ghg-reporting
EPA GHG web site: https://www.epa.gov/ghgreporting/forms/contact-us-about-ghg-reporting
Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
Yes
A brief description of the GHG inventory verification process:
The EPA provides the template for reporting green house gas emissions. The university enters actual metered data into the template. The EPA then certifies the results. The university Director of Operations enters the data which is checked by the AVP of Facilities Planning nd Management.
EPA GHG web site: https://www.epa.gov/ghgreporting/forms/contact-us-about-ghg-reporting
VERIFICATION OF REPORT RECEIPT AND CERTIFICATION:
Lowe, James
Sent: Tuesday, August 23, 2022 7:37 AM
To: Lowe, James
Subject: FW: e-GGRT: annual GHG report has been submitted to EPA (Ref# 1538913 (email id))
-----Original Message-----
From: eGGRT@ccdsupport.com
Sent: Tuesday, March 29, 2022 1:59 PM
To: Heuer, Pete
Cc: Lowe, James
Subject: e-GGRT: annual GHG report has been submitted to EPA (Ref# 1538913 (email id))
A Notice from EPA's Electronic Greenhouse Gas Reporting Tool (e-GGRT)
The 2021 GHG annual report for the following facility or supplier has been submitted, certified
and sent to EPA.
Reporting Year: 2021
Submission Number: 1
Confirmation Code: 352841-321322
GHG Facility ID: 526327
BALL STATE UNIVERSITY
2000 W UNIVERSITY AVE
MUNCIE, IN 47306
Designated Representative: Heuer, Pete
Alternate Designated Representative: Lowe, James
The report was submitted by Heuer, Pete on Tue Mar 29 13:55:36 EDT 2022.
You may submit revisions to your GHG annual report if there is a need to update your GHG data.
If you believe you received this message in error, or have questions, please contact the Help Desk
at ghgreporting@epa.gov, or by calling 1-877-444-1188, Monday through Friday during regular
business hours.
20042
EPA GHG web site: https://www.epa.gov/ghgreporting/forms/contact-us-about-ghg-reporting
VERIFICATION OF REPORT RECEIPT AND CERTIFICATION:
Lowe, James
Sent: Tuesday, August 23, 2022 7:37 AM
To: Lowe, James
Subject: FW: e-GGRT: annual GHG report has been submitted to EPA (Ref# 1538913 (email id))
-----Original Message-----
From: eGGRT@ccdsupport.com
Sent: Tuesday, March 29, 2022 1:59 PM
To: Heuer, Pete
Cc: Lowe, James
Subject: e-GGRT: annual GHG report has been submitted to EPA (Ref# 1538913 (email id))
A Notice from EPA's Electronic Greenhouse Gas Reporting Tool (e-GGRT)
The 2021 GHG annual report for the following facility or supplier has been submitted, certified
and sent to EPA.
Reporting Year: 2021
Submission Number: 1
Confirmation Code: 352841-321322
GHG Facility ID: 526327
BALL STATE UNIVERSITY
2000 W UNIVERSITY AVE
MUNCIE, IN 47306
Designated Representative: Heuer, Pete
Alternate Designated Representative: Lowe, James
The report was submitted by Heuer, Pete on Tue Mar 29 13:55:36 EDT 2022.
You may submit revisions to your GHG annual report if there is a need to update your GHG data.
If you believe you received this message in error, or have questions, please contact the Help Desk
at ghgreporting@epa.gov, or by calling 1-877-444-1188, Monday through Friday during regular
business hours.
20042
Documentation to support the GHG inventory verification process:
---
Scope 1 GHG emissions
Weight in MTCO2e | |
Stationary combustion | 13,993.95 Metric tons of CO2 equivalent |
Other sources (mobile combustion, process emissions, fugitive emissions) | 1,140.55 Metric tons of CO2 equivalent |
Total gross Scope 1 GHG emissions, performance year:
15,134.50
Metric tons of CO2 equivalent
Scope 2 GHG emissions
Weight in MTCO2e | |
Imported electricity | 59,366.95 Metric tons of CO2 equivalent |
Imported thermal energy | 0 Metric tons of CO2 equivalent |
Total gross Scope 2 GHG emissions, performance year:
59,366.95
Metric tons of CO2 equivalent
GHG emissions from biomass combustion
0
Metric tons of CO2 equivalent
Scope 3 GHG emissions
Yes or No | Weight in MTCO2e | |
Business travel | Yes | 1,977.11 Metric tons of CO2 equivalent |
Commuting | --- | 0 Metric tons of CO2 equivalent |
Purchased goods and services | Yes | 131.41 Metric tons of CO2 equivalent |
Capital goods | --- | 0 Metric tons of CO2 equivalent |
Fuel- and energy-related activities not included in Scope 1 or Scope 2 | --- | 0 Metric tons of CO2 equivalent |
Waste generated in operations | Yes | 2,132.26 Metric tons of CO2 equivalent |
Other sources | Yes | 5,871.46 Metric tons of CO2 equivalent |
Total Scope 3 GHG emissions, performance year:
10,112.24
Metric tons of CO2 equivalent
A brief description of how the institution accounted for its Scope 3 emissions:
Actual on campus data imported into SIMAP calculation tool.
Part 2. Air pollutant emissions inventory
Yes
Annual weight of emissions for::
Weight of Emissions | |
Nitrogen oxides (NOx) | 33 Tons |
Sulfur oxides (SOx) | 0.13 Tons |
Carbon monoxide (CO) | --- |
Particulate matter (PM) | 2.26 Tons |
Ozone (O3) | 0 Tons |
Lead (Pb) | 0 Tons |
Hazardous air pollutants (HAPs) | 0 Tons |
Ozone-depleting compounds (ODCs) | 0 Tons |
Other standard categories of air emissions identified in permits and/or regulations | 1 Tons |
Do the air pollutant emissions figures provided include the following sources?:
Yes or No | |
Major stationary sources | Yes |
Area sources | Yes |
Mobile sources | Yes |
Commuting | No |
Off-site electricity production | Yes |
None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
Ball State University greenhouse gas reports are submitted as required by the EPA and IDEM for Title V permit fees.
Optional Fields
59,366.95
Metric tons of CO2 equivalent
Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
0
Metric tons of CO2 equivalent
Website URL where information about the institution’s emissions inventories is available:
Additional documentation to support the submission:
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.