Part 1. Greenhouse gas emissions inventory

Has the institution conducted a GHG emissions inventory within the previous three years that includes all Scope 1 and 2 emissions? :
Yes

A copy of the most recent GHG emissions inventory:
A brief description of the methodology and/or tool used to complete the GHG emissions inventory:
The Coordinator for the Center of Environmental Studies collects data from campus offices, energy providers, etc., for entry into the SIMAP, managed by the Sustainability Institute of the University of New Hampshire. Summaries, spreadsheets, and accompanying narratives are available at the Second Nature website (https://reporting.secondnature.org/institution/detail!3759##3759)

Has the GHG emissions inventory been validated internally by personnel who are independent of the GHG accounting and reporting process and/or verified by an independent, external third party?:
No

A brief description of the GHG inventory verification process:
---

Documentation to support the GHG inventory verification process:
---

Scope 1 GHG emissions
Gross Scope 1 GHG emissions, performance year:
Weight in MTCO2e
Stationary combustion 2,433.60 Metric tons of CO2 equivalent
Other sources (mobile combustion, process emissions, fugitive emissions) 41 Metric tons of CO2 equivalent

Total gross Scope 1 GHG emissions, performance year:
2,474.60 Metric tons of CO2 equivalent

Scope 2 GHG emissions
Gross Scope 2 GHG emissions, performance year (market-based):
Weight in MTCO2e
Imported electricity 0 Metric tons of CO2 equivalent
Imported thermal energy 0 Metric tons of CO2 equivalent

Total gross Scope 2 GHG emissions, performance year:
0 Metric tons of CO2 equivalent

GHG emissions from biomass combustion
Gross GHG emissions from biogenic sources, performance year:
0 Metric tons of CO2 equivalent

Scope 3 GHG emissions
Does the GHG emissions inventory include Scope 3 emissions from the following sources?:
Yes or No Weight in MTCO2e
Business travel Yes 1,392.56 Metric tons of CO2 equivalent
Commuting Yes 596.09 Metric tons of CO2 equivalent
Purchased goods and services Yes 0 Metric tons of CO2 equivalent
Capital goods --- 0 Metric tons of CO2 equivalent
Fuel- and energy-related activities not included in Scope 1 or Scope 2 Yes 333.21 Metric tons of CO2 equivalent
Waste generated in operations Yes 0 Metric tons of CO2 equivalent
Other sources No 0 Metric tons of CO2 equivalent

Total Scope 3 GHG emissions, performance year:
2,321.86 Metric tons of CO2 equivalent

A brief description of how the institution accounted for its Scope 3 emissions:
Scope 3 emissions are currently calculated using the following methods:
-Commuting data: A survey was designed and sent via email to all faculty, staff, and students that live off campus in the spring of 2017. We hope to perform another survey this spring when campus populations have normalized.
-Air/bus travel for athletics and study abroad are calculated based on arrival/departure information provided by the respective departments. Personal vehicle reimbursement mileage is based on an estimate from data previously collected by the Business Office.
-Information about wastewater and solid waste is available from the college's Physical Plant and based on methods outlined in the inventory attached above.

Part 2. Air pollutant emissions inventory

Has the institution completed an inventory within the previous three years to quantify its air pollutant emissions?:
No

Annual weight of emissions for::
Weight of Emissions
Nitrogen oxides (NOx) ---
Sulfur oxides (SOx) ---
Carbon monoxide (CO) ---
Particulate matter (PM) ---
Ozone (O3) ---
Lead (Pb) ---
Hazardous air pollutants (HAPs) ---
Ozone-depleting compounds (ODCs) ---
Other standard categories of air emissions identified in permits and/or regulations ---

Do the air pollutant emissions figures provided include the following sources?:
Yes or No
Major stationary sources ---
Area sources ---
Mobile sources ---
Commuting ---
Off-site electricity production ---

None
A brief description of the methodology(ies) the institution used to complete its air emissions inventory:
---

Optional Fields

Gross Scope 2 GHG emissions from purchased electricity (location-based):
6,155.64 Metric tons of CO2 equivalent

Gross Scope 2 GHG emissions from imported thermal energy (location-based) :
0 Metric tons of CO2 equivalent

Website URL where information about the institution’s emissions inventories is available:
Additional documentation to support the submission:
---

Data source(s) and notes about the submission:
---

The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.