0.00 / 4.00 |
Jim
Dees Data and Assessment Specialist Office of Sustailability |
"---"
indicates that no data was submitted for this field
Total energy consumption (all sources, excluding transportation fuels), performance year :
628,215.30
MMBtu
Option 1
449.70
MMBtu
None
A brief description of on-site renewable electricity generating devices :
Wind:
The 100-kilowatt “Northwind 100” wind turbine
Solar:
yearly production data for 3 systems is included in the figure above
4.0 kW ground mounted system "mountain array"
1.7 kW pole mounted "biodiesel array"
5.4 kW roof mounted system "Legends PVEV Charging Station"
1.5 kW roof mounted "Kerr Scott array"
6.6 kW roof mounted "Library Traffic Circle array"
Option 2
212.10
MMBtu
None
A brief description of on-site renewable non-electric energy devices:
All other accountable RE is from solar thermal
Plemmons Student Union ST: 42 10'x4' FP collectors
Varsity Gymnasium ST: 12 10'x4' FP collectors
Reich College of Education ST: 4 8'x4' FP collectors
Biofuels Research Facility ST: 4 8'x4' FP collectors
Summit Residence Hall 72 panel pressutized glycol system
Mountaineer Residence Hall 40 panel pressurized glycol system
Option 3
0
MMBtu
None
A brief description of off-site, institution-catalyzed, renewable electricity generating devices:
---
Option 4
0
MMBtu
A brief description of the RECs, GOs and/or similar renewable energy products, including contract timeframes:
Option 4 is zero.
Optional Fields
Additional documentation to support the submission:
---
Sierra magazine requests the following information from U.S. institutions that wish to share data with that organization:
Percentage of total electricity use (0-100) | |
Biomass | 0 |
Coal | 30 |
Geothermal | 0 |
Hydro | 6 |
Natural gas | 12 |
Nuclear | 52 |
Solar photovoltaic | 0.04 |
Wind | 0.10 |
Other (please specify and explain below) | --- |
A brief description of other sources of electricity not specified above:
---
Energy used for heating buildings, by source::
Percentage of total energy used to heat buildings (0-100) | |
Biomass | 0 |
Coal | 0 |
Electricity | 7.70 |
Fuel oil | 0.20 |
Geothermal | 0.20 |
Natural gas | 91.90 |
Other (please specify and explain below) | --- |
A brief description of other sources of building heating not specified above:
---
Percentage of total energy consumption from clean and renewable sources:
0.11
Data source(s) and notes about the submission:
---
The information presented here is self-reported. While AASHE staff review portions of all STARS reports and institutions are welcome to seek additional forms of review, the data in STARS reports are not verified by AASHE. If you believe any of this information is erroneous or inconsistent with credit criteria, please review the process for inquiring about the information reported by an institution or simply email your inquiry to stars@aashe.org.